DTC Code | DTC Name |
---|---|
RECOVERY INSPECTION |
CAUTION / NOTICE / HINT
CAUTION:
When disposing of an HV supply stack sub-assembly, make sure to return it through an authorized collection agent who is capable of handling it safely. If it is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
Before returning an HV supply stack sub-assembly, make sure to perform a pre-return inspection.
Accidents such as electric shock may result if an HV supply stack sub-assembly is discharged improperly and disposed or abandoned.
Therefore, make sure to return all HV supply stack sub-assemblies through an authorized collection agent.
To reduce the risk of fire, HV supply stack sub-assemblies must not be stored in an area where they will be exposed to fire or high temperatures.
If the temperature of an HV supply stack sub-assembly is high, leave it to cool down.
Tech Tips
In order to return an HV supply stack sub-assembly in a safe manner, it may be necessary to discharge it. The following pre-return inspection procedure can be used to determine whether or not it is necessary to discharge an HV supply stack sub-assembly the method that may be required.
PROCEDURE
INSPECT FOR ELECTROLYTE LEAK
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Inspect for electrolyte leaks after removing the HV supply stack sub-assembly.
OK |
---|
No leak was found on the lower part of the battery outer case. |
CAUTION:
Perform this procedure in an area where the battery will not be exposed to fire.
Do not touch the HV supply stack sub-assembly, unless absolutely necessary, as electrolyte may be leaking.
Note
If there is an electrolyte leak, make sure to wear insulated gloves and goggles and clean it using a piece of cloth. Do not leave electrolyte-contaminated cloths unattended. Dispose of them according to law or local regulations.
Result | |||
---|---|---|---|
|
NG |
DISCHARGING (WHEN USING THE SALT WATER SOLUTION) |
OK |
CHECK FOR DTCS
Check the previously recorded DTCs which resulted in replacement of the HV supply stack sub-assembly.
Result | ||||||||
---|---|---|---|---|---|---|---|---|
|
DTC No. |
---|
P1A6017 |
P31AA17 |
P0C3000 |
P31B300 |
P1C7D49 |
B |
GO TO STEP 5 Click here |
C |
HV SUPPLY STACK SUB-ASSEMBLY CONNECTORS VISUAL CHECK Click here |
A |
CHECK HV SUPPLY STACK SUB-ASSEMBLY VOLTAGE
CAUTION:
Be sure to wear insulated gloves and protective goggles.
*1 | No. 1 HV Supply Stack Sub-assembly |
*2 | No. 2 HV Supply Stack Sub-assembly |
Measure the voltage according to the value(s) in the table below.
Standard Voltage | |||||||
---|---|---|---|---|---|---|---|
|
CAUTION:
Make sure not to cross the probes of the electrical tester.
Result | |||
---|---|---|---|
|
NG |
GO TO STEP 6 Click here |
OK |
INSULATION INSPECTION OF HV SUPPLY STACK SUB-ASSEMBLY
CAUTION:
Be sure to wear insulated gloves and protective goggles.
*a | Insulation Inspection Area of the Bracket |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance | |||||||
---|---|---|---|---|---|---|---|
|
Result | |||
---|---|---|---|
|
NG |
GO TO STEP 6 Click here |
OK |
HV SUPPLY STACK SUB-ASSEMBLY VISUAL CHECK
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Check that the HV supply stack sub-assembly is not deformed or damaged.
OK |
---|
The HV supply stack sub-assembly is not deformed or damaged. |
Result | |||
---|---|---|---|
|
OK |
RETURN HV SUPPLY STACK SUB-ASSEMBLY |
NG |
HV SUPPLY STACK SUB-ASSEMBLY CONNECTORS VISUAL CHECK
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Check that the orange connectors connected to the battery ECU assembly are not deformed or damaged.
OK |
---|
The connectors are not deformed or damaged. |
Tech Tips
If any of the connectors are damaged, a Li-ion battery discharger will not be able to be connected to the HV supply stack sub-assembly. Soak the HV supply stack sub-assembly in a saltwater solution to discharge it.
Result | |||
---|---|---|---|
|
OK |
DISCHARGING (WHEN USING THE LI-ION BATTERY DISCHARGER) |
NG |