CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are replaced during millimeter wave radar sensor assembly removal/installation are shown below.
Replaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
---|---|---|---|
Millimeter wave radar sensor assembly | Adjust millimeter wave radar sensor assembly |
|
PROCEDURE
REMOVE RADIATOR SUPPORT OPENING COVER
REMOVE MILLIMETER WAVE RADAR SENSOR ASSEMBLY
Disconnect the connector.
Bolt | |
Screw |
Remove the 2 bolts and 2 screws.
Disengage the 2 guides and remove the millimeter wave radar sensor assembly.
Note
Do not reuse the millimeter wave radar sensor assembly if it has been dropped or subjected to a severe impact.