PROCEDURE
PRECAUTION
CAUTION:
Be sure to read Precaution thoroughly before servicing Click here.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
REMOVE INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY
DISCONNECT NO. 2 INSTRUMENT PANEL WIRE
Check that the power switch is off.
Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
CAUTION:
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
*1 | Slider |
Slide the slider to release the lock, and then disconnect the connector.
Note
When disconnecting any airbag connector, take care not to damage the airbag wire harness.
REMOVE INSTRUMENT PANEL SAFETY PAD ASSEMBLY
REMOVE INSTRUMENT PANEL PASSENGER AIRBAG ASSEMBLY
CAUTION:
When storing the instrument panel passenger airbag assembly, keep the airbag deployment side facing upward.
Remove the 2 screws and disengage the 2 clamps.
Lean the instrument panel safety pad assembly and disengage the 3 hooks.
Disengage the 3 hooks to remove the instrument panel passenger airbag assembly from the instrument panel safety pad assembly.
REMOVE NO. 2 INSTRUMENT PANEL WIRE
*1 | Protective Tape |
*2 | Airbag Connector |
*3 | Airbag Connector Lock |
Disengage the clamp.
Using a screwdriver with its tip wrapped with protective tape, release the 2 airbag connector locks.
Disconnect the 2 airbag connectors to remove the No. 2 instrument panel wire from the instrument panel passenger airbag assembly.
Note
When disconnecting any airbag connector, take care not to damage the airbag wire harness.