PROCEDURE
INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/o Active Height Control)
*a | Component without harness connected (Integration Control and Panel Assembly) |
Measure the resistance according to the value(s) in the table below.
Tester Connection | Switch Condition | Specified Condition |
---|---|---|
5 (E) - 6 (P) | Mode switch (ECT PWR) on |
Below 1 Ω |
Release mode switch (ECT PWR) off |
10 kΩ or higher | |
5 (E) - 8 (2nd) | Mode switch being pushed and held (ECT 2nd) |
Below 1 Ω |
Mode switch not pushed (ECT 2nd) |
10 kΩ or higher |
If the result is not as specified, replace the integration control and panel assembly.
INSPECT INTEGRATION CONTROL AND PANEL ASSEMBLY (w/ Active Height Control)
*a | Component without harness connected (Integration Control and Panel Assembly) |
Measure the resistance according to the value(s) in the table below.
Tester Connection | Switch Condition | Specified Condition |
---|---|---|
5 (E) - 6 (P) | Mode switch being pushed and held (SPORTS S/S+) |
Below 1 Ω |
Mode switch not pushed (SPORTS S/S+) |
10 kΩ or higher | |
5 (E) - 2 (B) | Mode switch being pushed and held (NORMAL) |
Below 1 Ω |
Mode switch not pushed (NORMAL) |
10 kΩ or higher | |
5 (E) - 3 (ECU) | Mode switch being pushed and held (COMF/ECO) |
Below 1 Ω |
Mode switch not pushed (COMF/ECO) |
10 kΩ or higher |
If the result is not as specified, replace the integration control and panel assembly.