PROCEDURE
PERFORM REGISTRATION
PRECAUTION
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE AIR CLEANER CAP SUB-ASSEMBLY
Disconnect the mass air flow meter connector and detach the wire harness clamp.
Detach the 2 clamps.
Loosen the hose clamp and remove the air cleaner cap sub-assembly.
REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
REMOVE AIR CLEANER CASE SUB-ASSEMBLY
Remove the 3 bolts and air cleaner case sub-assembly.
REMOVE ECM
Push | |
Raise |
Raise the 2 levers while pushing the locks on the levers, and disconnect the 2 ECM connectors.
Note
After disconnecting the ECM connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the ECM connectors.
Detach the claw and disconnect the relay.
Remove the 3 bolts and ECM.
Note
Avoid physical shock to the ECM.
Remove the 2 screws and No. 1 ECM bracket from the ECM.
Remove the 2 screws and No. 2 ECM bracket from the ECM.