ГЕНЕРАТОР СНЯТИЕ

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed, installed, or replaced during the generator assembly removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replacement Part or Procedure Necessary Procedures Effects/Inoperative when not Performed Link
Battery terminal is disconnected/reconnected Drive the vehicle until stop and start control is permitted (approximately 15 to 40 minutes) Stop and start system

Click here

Memorize steering angle neutral point Panoramic view monitor system

Click here

Initialize back door lock Power door lock control system

Click here

Initialize servo motor Air conditioning system

Click here

Reset slide door close position Power slide door system

Click here

Reset back door close position Power back door system

Click here

PROCEDURE


  1. PRECAUTION

    Note

    After turning the engine switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE RADIATOR COVER SUB-ASSEMBLY (for ALPHARD)

    Click here

  4. REMOVE RADIATOR COVER SUB-ASSEMBLY (for VELLFIRE)

    Click here

  5. REMOVE V-RIBBED BELT

    Click here

  6. REMOVE GENERATOR ASSEMBLY


    1. B006QR8

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the generator assembly connector.

    4. Remove the bolt and disconnect the wire harness clamp bracket from the generator assembly.

    5. B006QDR

      Remove the 2 bolts and generator assembly.