ECM REMOVAL


  1. REMOVE RADIATOR SUPPORT OPENING COVER


    1. A00OKW2

      Remove the 7 clips and radiator support opening cover.

  2. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

  3. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  4. REMOVE NO. 2 CYLINDER HEAD COVER


    1. A00OIJQ

      Hold the rear of the cover and raise it to detach the 2 clips on the rear of the cover. Continue to raise the cover to detach the 2 clips on the front of the cover and remove the cover.

      Note

      Attempting to detach both front and rear clips at the same time may cause the cover to break.

  5. REMOVE AIR CLEANER CAP SUB-ASSEMBLY


    1. A00OKGM

      Disconnect the mass air flow meter connector.

    2. Detach the wire harness from the 2 clamps.

    3. A00OMGP

      Disconnect the 2 clamps.

    4. A00OKSA

      Disconnect the ventilation hose.

    5. Loosen the band and remove the air cleaner cap.

  6. REMOVE AIR CLEANER CASE SUB-ASSEMBLY


    1. A00OI1G

      Detach the wire harness clamp from the air cleaner case.

    2. Remove the 3 bolts and air cleaner case.

  7. REMOVE NO. 1 AIR CLEANER INLET


    1. A00OHQP

      Remove the clip.

    2. Detach the 2 claws and remove the No. 1 air cleaner inlet.

  8. DISCONNECT NO. 2 AIR CLEANER INLET


    1. A00OHVG

      Remove the bolt and disconnect the No. 2 air cleaner inlet from the vehicle body.

  9. REMOVE ECM


    1. A00OMTS

      for Manual Transaxle:

      Disconnect the wire harness clamp.

    2. Disconnect the 2 ECM connectors.


      1. A00OMLF

        Raise the 2 levers while pushing the locks on the levers and disconnect the 2 ECM connectors.

        Note

        After disconnecting the connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the connectors.

    3. A00OKZP

      Remove the 2 bolts and ECM.

    4. A00OHXAE01

      Remove the 4 screws, No. 1 ECM bracket and No. 2 ECM bracket.