DESCRIPTION
This circuit is the power source circuit for the combination meter.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
*1 | Front view of wire harness connector (to Combination Meter Assembly) |
Disconnect the D1 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
Standard Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value in the table below.
Standard Resistance | ||||||
---|---|---|---|---|---|---|
|
Reconnect the combination meter assembly connector.
NG |
REPAIR OR REPLACE HARNESS OR CONNECTOR |
OK |
REPLACE COMBINATION METER ASSEMBLY Click here