INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY (ALL DOORS))
Note
When a door window regulator assembly, power window regulator motor assembly, door glass or door glass run is reinstalled or replaced, the power window control system must be initialized. Functions such as the auto up and down, jam protection, remote control and key-off operation will not operate if initialization is not performed.
When a power window regulator motor assembly is replaced, DTC B2313 is stored. Clear the DTC after initialization.
When performing initialization, do not perform any other procedures.
When performing initialization, use the power window switch of each door to initialize each door window.
If initialization is not completed properly, the LIN communication system may have a malfunction Click here.
Make sure to park the vehicle and turn off all the electrical systems before performing initialization. Initialization will be canceled if the vehicle is driven during initialization.
Make sure not to hit, strike or vibrate the door window glass during initialization because the vehicle is learning the sliding resistance of the door window glass.
Make sure not to turn the ignition switch to ON or off during initialization.
Tech Tips
If the battery has been replaced, it is not necessary to initialize the power window regulator motor assembly.
Perform initialization according to the table below.
Condition of Power Window | Proceed to |
---|---|
Initialization method when a power window regulator motor assembly has been replaced with a new one. | Procedure A |
Initialization method when a power window regulator motor assembly has been removed/installed or a door glass and/or door glass run etc. have been removed/installed or replaced with new ones. Tech Tips Use this procedure if the power window regulator motor assembly has been reused. |
Procedure B |
Initialization method when a reverse rotation malfunction occurs due to a sliding resistance change resulting from adjustment etc. | Procedure C |
Procedure A
Connect the battery and turn the ignition switch ON.
Fully open the power window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the power window is fully closed to reset the glass position and complete initialization.
Procedure B
Connect the battery and turn the ignition switch to ON.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled up, release the switch and fully pull it again).
Fully open the window by pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Release the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.
Procedure C
Connect the battery and turn the ignition switch to ON.
Fully open the window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.