3ZR-FAE STARTING SERVICE DATA
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
Battery positive (+) terminal - Terminal 30 - Terminal SL2 |
11.5 V |
Below 130 A |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
Segment - Segment |
Always |
Below 1 Ω |
Segment - Starter armature core |
10 kΩ or higher |
Commutator for runout |
Maximum Runout |
0.05 mm (0.00197 in.) |
Commutator diameter |
Standard Diameter |
29 mm (1.1417 in.) |
Minimum Diameter |
28 mm (1.1024 in.) |
Undercut depth |
Standard Undercut Depth |
0.7 mm (convex part) (0.0276 in.) |
Minimum Undercut Depth |
0.4 mm (convex part) (0.0157 in.) |
Brush length |
Standard Length |
14.4 mm (0.567 in.) |
Minimum Length |
9 mm (convex part) (0.354 in.) |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
A - B A - C B - D C - D |
Always |
10 kΩ or higher |
A - D B - C |
Below 1 Ω |
Brush spring load |
Standard Spring Load |
22 to 27 N (2 to 3 kgf, 4.9 to 6.1 lbf) |
Minimum Spring Load |
14 N (1 kgf, 3.1 lbf) |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
Terminal SL1 - Magnet switch body |
Always |
Below 1 Ω |
Terminal SL2 - Magnet switch body |
Below 2 Ω |
Tester Connection |
Switch Condition |
Specified Condition |
|---|---|---|
5 (SS1) - 6 (AGND) |
Not pushed |
10 kΩ or higher |
1 (SS2) - 6 (AGND) |
||
5 (SS1) - 6 (AGND) |
Pushed |
Below 1 Ω |
1 (SS2) - 6 (AGND) |
Condition |
Specified Condition |
|---|---|
Battery positive (+) → Terminal 9 (SWIL) Battery negative (-) → Terminal 6 (AGND) |
Illuminates |
Tester Connection |
Switch Condition |
Specified Condition |
|---|---|---|
All combinations of all terminals |
LOCK |
10 kΩ or higher |
5 (AM1) - 7 (ACC) |
ACC |
Below 1 Ω |
5 (AM1) - 7 (ACC) |
ON |
Below 1 Ω |
5 (AM1) - 8 (IG1) |
||
4 (AM2) - 3 (IG2) |
||
6 (ST1) - 5 (AM1) |
STRAT |
Below 1 Ω |
6 (ST1) - 8 (IG1) |
||
2 (ST2) - 4 (AM2) |
||
2 (ST2) - 3 (IG2) |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
3 - 5 |
Battery voltage not applied to terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied to terminals 1 and 2 |
Below 1 Ω |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
3 - 5 |
Battery voltage not applied to terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied to terminals 1 and 2 |
Below 1 Ω |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|
3 - 5 |
Battery voltage not applied to terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied to terminals 1 and 2 |
Below 1 Ω |