3ZR-FAE STARTING SERVICE DATA

Table 1. STARTER ASSEMBLY

Tester Connection

Condition

Specified Condition

Battery positive (+) terminal - Terminal 30 - Terminal SL2

11.5 V

Below 130 A

Table 2. STARTER ARMATURE ASSEMBLY

Tester Connection

Condition

Specified Condition

Segment - Segment

Always

Below 1 Ω

Segment - Starter armature core

10 kΩ or higher

Commutator for runout

Maximum Runout

0.05 mm (0.00197 in.)

Commutator diameter

Standard Diameter

29 mm (1.1417 in.)

Minimum Diameter

28 mm (1.1024 in.)

Undercut depth

Standard Undercut Depth

0.7 mm (convex part) (0.0276 in.)

Minimum Undercut Depth

0.4 mm (convex part) (0.0157 in.)

Table 3. STARTER BRUSH HOLDER ASSEMBLY

Brush length

Standard Length

14.4 mm (0.567 in.)

Minimum Length

9 mm (convex part) (0.354 in.)

Tester Connection

Condition

Specified Condition

A - B

A - C

B - D

C - D

Always

10 kΩ or higher

A - D

B - C

Below 1 Ω

Brush spring load

Standard Spring Load

22 to 27 N (2 to 3 kgf, 4.9 to 6.1 lbf)

Minimum Spring Load

14 N (1 kgf, 3.1 lbf)

Table 4. REPAIR SERVICE STARTER KIT

Tester Connection

Condition

Specified Condition

Terminal SL1 - Magnet switch body

Always

Below 1 Ω

Terminal SL2 - Magnet switch body

Below 2 Ω

Table 5. ENGINE SWITCH

Tester Connection

Switch Condition

Specified Condition

5 (SS1) - 6 (AGND)

Not pushed

10 kΩ or higher

1 (SS2) - 6 (AGND)

5 (SS1) - 6 (AGND)

Pushed

Below 1 Ω

1 (SS2) - 6 (AGND)

Condition

Specified Condition

Battery positive (+) → Terminal 9 (SWIL)

Battery negative (-) → Terminal 6 (AGND)

Illuminates

Table 6. IGNITION SWITCH

Tester Connection

Switch Condition

Specified Condition

All combinations of all terminals

LOCK

10 kΩ or higher

5 (AM1) - 7 (ACC)

ACC

Below 1 Ω

5 (AM1) - 7 (ACC)

ON

Below 1 Ω

5 (AM1) - 8 (IG1)

4 (AM2) - 3 (IG2)

6 (ST1) - 5 (AM1)

STRAT

Below 1 Ω

6 (ST1) - 8 (IG1)

2 (ST2) - 4 (AM2)

2 (ST2) - 3 (IG2)

Table 7. STARTER RELAY (ST) (w/o Stop and Start System)

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applied to terminals 1 and 2

Below 1 Ω

Table 8. STARTER NO. 1 RELAY (ST NO. 1) (w/ Stop and Start System)

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applied to terminals 1 and 2

Below 1 Ω

Table 9. STARTER NO. 2 RELAY (ST NO. 2) (w/ Stop and Start System)

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applied to terminals 1 and 2

Below 1 Ω