GENERATOR INSPECTION
PROCEDURE
INSPECT GENERATOR REGULATOR ASSEMBLY
-
*a
Length
Using a vernier caliper, measure the length of the exposed brushes.
Standard Exposed Brush Length
11.2 mm (0.441 in.)
Minimum Exposed Brush Length
2.0 mm (0.0787 in.)
If the brush length is less than the minimum, replace the generator regulator assembly.
-