CAMSHAFT OIL CONTROL VALVE INSPECTION
PROCEDURE
INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
6.9 to 7.9 Ω
If the result is not as specified, replace the oil control valve assembly.
-
Check the operation.
Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
OK
Measurement Condition
Specified Condition
Battery positive (+) voltage is applied
Valve moves in left arrow direction shown in illustration
Battery positive (+) voltage is cut off
Valve moves in right arrow direction shown in illustration
Table 1. Text in Illustration *1
Component without harness connected
(Camshaft Timing Oil Control Valve)
Note:Confirm that the valve moves freely and does not stick in any position.
If the result is not as specified, replace the oil control valve assembly.
Tip:Accumulation of foreign matter causes subtle pressure leaks. The subtle pressure leaks will cause the camshaft to advance, and this will cause a DTC to be stored.