BLIND SPOT MONITOR SYSTEM, Diagnostic DTC:C1AB7
| DTC Code | DTC Name |
|---|---|
| C1AB7 | Blind Spot Monitor Slave Module |
DESCRIPTION
This DTC is stored when the blind spot monitor sensor RH detects an internal malfunction.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
Note |
|---|---|---|---|---|
C1AB7 |
Blind Spot Monitor Slave Module |
The blind spot monitor sensor RH (slave) detects an internal malfunction |
Blind spot monitor sensor RH |
- |
CAUTION / NOTICE / HINT
Note:
When checking for DTCs, make sure that the blind spot monitor main switch (multi-function switch) is on.
PROCEDURE
CHECK DTC
Clear the DTCs.
Recheck for DTCs and check if the same DTC is output again.
OK
DTC C1AB7 is not output.
Result
Proceed to
OK
NG