GENERATOR INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
-
Insert the bolt (A) to the generator assembly as shown in the illustration.
-

Set in this Direction
Set the generator assembly with bolt (A) to the engine assembly as shown in the illustration.
Tip:As there is not enough clearance to insert the bolt (A) after setting the generator assembly to the engine assembly, set the generator assembly to the engine assembly with the bolt (A) inserted.
-
Using an E12 "TORX" socket wrench, tighten the bolt (A) and install the bolt (B).
38 N*m
387 kgf*cm
28 ft.*lbf
Connect the generator assembly connector.
Connect the wire harness to terminal B with the nut.
12.7 N*m
130 kgf*cm
9 ft.*lbf
Install the terminal cap.
-
INSTALL V-RIBBED BELT
INSTALL NO. 1 ENGINE COVER
INSTALL RADIATOR ASSEMBLY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.