PROCEDURE
INSTALL AIR FUEL RATIO SENSOR
| *a | Fulcrum Length 30 mm |
| *b | Fulcrum Length 300 mm |
Using SST, install the air fuel ratio sensor.
Note
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.) and a torque wrench with a fulcrum length of 300 mm (11.8 in.) Click here.
The "with SST" torque value is effective when SST is parallel to the torque wrench.
Connect the air fuel ratio sensor connector and clamp.
INSTALL NO. 2 CYLINDER HEAD COVER
INSPECT FOR EXHAUST GAS LEAK
INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY (for LHD)
INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY (for RHD)
INSTALL COWL BODY MOUNTING REINFORCEMENT LH (for LHD)
INSTALL COWL BODY MOUNTING REINFORCEMENT RH (for RHD)
INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY