UREA PUMP CONTROL ECU REMOVAL

PROCEDURE


  1. REMOVE UREA TANK SUB-ASSEMBLY

    Click here

  2. REMOVE NO. 2 UREA PUMP CONTROL BRACKET


    1. A01SGOI

      Remove the 2 nuts and No. 2 urea pump control bracket from the No. 1 urea pump control bracket.

  3. REMOVE UREA PUMP CONTROL ECU


    1. A01SI24

      Raise the lever while pushing the lock on the lever and disconnect the connector from the urea pump control ECU.

      Note

      After disconnecting a connector, make sure that dirt, water and other foreign matter does not contact the connector.

    2. A01SJUX

      Remove the 3 nuts and No. 1 urea pump control bracket from the urea tank sub-assembly.

    3. A01SI0G

      Remove the 2 bolts and urea pump control ECU from the No. 1 urea pump control bracket.