GENERATOR INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
-
Install the generator assembly with the 2 bolts.
for bolt A
35 N*m
357 kgf*cm
26 ft.*lbf
for bolt B
54 N*m
551 kgf*cm
40 ft.*lbf
-
Connect the wire harness to terminal B and install the nut.
9.8 N*m
100 kgf*cm
87 in.*lbf
Connect the connector and 2 clamps.
Install the terminal cap.
-
INSTALL V-RIBBED BELT
INSTALL NO. 1 ENGINE COVER (w/ No. 1 Engine Cover)
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.