CHARGING SYSTEM TERMINALS OF ECU

  1. TERMINAL INSPECTION

    E263238E01
    1. Measure the voltage and resistance according to the value(s) in the table below.

      Tip:

      The standard normal voltage between each pair of generator control ECU assembly terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks should be compared with the standard normal voltage for that pair of terminals, displayed in the Specified Condition column. The illustration above can be used as a reference to identify the generator control ECU assembly terminal locations.

      Terminal No. (Symbol)

      Wiring Color

      Terminal Description

      Condition

      Specified Condition

      A58-1 (ACC) - Body ground

      GR - Body ground

      Constant power source

      Ignition switch ACC

      11 to 14 V

      A58-2 (CA3N) - A58-3 (CA3P)

      W - B

      CAN communication signal

      Ignition switch off

      (while CAN communication is stopped)

      108 to 132 Ω

      A58-5 (AM21) - Body ground

      W - Body ground

      Constant power source

      Always

      11 to 14 V

      A58-6 (LIN1) - Body ground

      L - Body ground

      LIN communication signal

      Ignition switch off

      (while LIN communication is stopped)

      10 kΩ or higher

      A58-9 (INH) - Body ground

      P - Body ground

      Wiper operation signal

      Ignition switch ON, wiper switch HI

      11 to 14 V