METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DTC Code DTC Name
Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.

WIRING DIAGRAM

E254195E05

CAUTION / NOTICE / HINT

Note:

Inspect the fuses of circuits related to this system before performing the following procedure.

PROCEDURE

  1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)

    1. E254928C02

      *a

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the E46 combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      E46-21(ET) - Body ground

      Always

      Below 1 Ω

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection

      Condition

      Specified Condition

      E46-39 (IG+) - Body ground

      Ignition switch off

      Below 1 V

      Ignition switch ON

      11 to 14 V

      E46-40 (B) - Body ground

      Always

      11 to 14 V

    Result

    Proceed to

    OK

    NG

    OK

    REPLACE COMBINATION METER ASSEMBLY

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR