METER / GAUGE SYSTEM Entire Combination Meter does not Operate
| DTC Code | DTC Name |
|---|---|
| Entire Combination Meter does not Operate |
DESCRIPTION
This circuit is the power source circuit for the combination meter assembly. This circuit provides two types of power sources; one is a constant power source, and the other is an IG power source.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses of circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY CIRCUIT)
-
*a
Front view of wire harness connector
(to Combination Meter Assembly)
Disconnect the E46 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
E46-21(ET) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
E46-39 (IG+) - Body ground
Ignition switch off
Below 1 V
Ignition switch ON
11 to 14 V
E46-40 (B) - Body ground
Always
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-