COMMON RAIL INSPECTION


  1. INSPECT COMMON RAIL ASSEMBLY


    1. B007THNE09
      Text in Illustration
      *a

      Component without harness connected

      (Fuel Pressure Sensor)

      Inspect the fuel pressure sensor.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        5 (PR) - 4 (E2) 25°C (77°F) 16.4 kΩ or less
        2 (PR2) - 3 (E2S) 16.4 kΩ or less
        6 (VC) - 5 (PR) 3 kΩ or less
        1 (VCS) - 2 (PR2) 3 kΩ or less

        If the result is not as specified, replace the common rail assembly.

    2. Inspect the pressure discharge valve.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1 - 2 20°C (68°F) 0.42 to 0.52 Ω

        Tech Tips

        The temperature indicated in "Condition" is the temperature of the pressure discharge valve.

        If the result is not as specified, replace the common rail assembly.