CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER INSPECTION

PROCEDURE

  1. INSPECT CONTINUOUSLY VARIABLE VALVE LIFT CONTROLLER ASSEMBLY

    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Powertrain / Engine and ECT / Active Test / Activate the VALVEMATIC (ENG OFF) (Click here).

      Note:
      • Make sure to perform the "Activate the VALVEMATIC (ENG OFF)" Active Test with the continuously variable valve lift controller removed from the vehicle.

      • Perform the Active Test with the body of the continuously variable valve lift controller connected to ground, as the continuously variable valve lift controller is grounded through the body.

        Table 1. OK

        Tester Operation

        Specified Condition

        Low

        VALVEMATIC Current Angle is 100 to 120°CA and shaft extends

        High

        VALVEMATIC Current Angle is 250°CA or more and shaft retracts