INTAKE AIR TEMPERATURE SENSOR INSPECTION
PROCEDURE
INSPECT FOR INTAKE AIR TEMPERATURE SENSOR
Partially immerse the sensor in water and warm up the water.
*a
Component without harness connected
(Intake Air Temperature Sensor)
*b
Resistance kΩ
*c
Temperature °C (°F)
*d
Acceptable Range
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (THA) - 2 (E2)
Approximately 20°C (68°F)
2.21 to 2.65 kΩ
Approximately 60°C (140°F)
0.55 to 0.61 kΩ
Note:When checking the intake air temperature sensor in water, keep the terminals dry. After the check, wipe the intake air temperature sensor dry.
If the result is not as specified, replace the intake air temperature sensor.