AIR FUEL RATIO SENSOR INSPECTION
PROCEDURE
INSPECT AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
-
*a
Component without harness connected
(Air Fuel Ratio Sensor)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (HA1A) - 2 (+B)
20°C (68°F)
1.6 to 3.2 Ω
If the result is not as specified, replace the air fuel ratio sensor.
-