POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION
PROCEDURE
INSPECT FRONT POWER WINDOW REGULATOR ASSEMBLY LH
-
Check that the window regulator moves smoothly as follows.
Note:Do not apply positive (+) battery voltage to any terminal other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
OK
Measurement Condition
Specified Condition
Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 10 (UP).
Disconnect and reconnect the negative (-) battery terminal to terminal 10 (UP) within 1 second.
Arm of window regulator rotates clockwise (Up)
Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 7 (DOWN).
Disconnect and reconnect the negative (-) battery terminal to terminal 7 (DOWN) within 1 second.
Arm of window regulator rotates counterclockwise (Down)
If the result is not as specified, replace the regulator.
CAUTION:Reset the door window regulator (initialize the pulse sensor) after installing the door window regulator to the door.
-
INSPECT FRONT POWER WINDOW REGULATOR ASSEMBLY RH
-
Check that the window regulator moves smoothly as follows.
Note:Do not apply positive (+) battery voltage to any terminal other then terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
OK
Measurement Condition
Specified Condition
Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 10 (UP).
Disconnect and reconnect the negative (-) battery terminal to terminal 10 (UP) within 1 second.
Arm of window regulator rotates counterclockwise (Up)
Connect the positive (+) battery terminal to terminal 2 (B), and connect the negative (-) battery terminal to terminal 1 (GND), and keep them connected for 3 seconds or more.
With terminals 2 (B) and 1 (GND) connected to the battery, connect the negative (-) battery terminal to terminal 7 (DOWN).
Disconnect and reconnect the negative (-) battery terminal to terminal 7 (DOWN) within 1 second.
Arm of window regulator rotates clockwise (Down)
If the result is not as specified, replace the regulator.
CAUTION:Reset the door window regulator (initialize the pulse sensor) after installing the door window regulator to the door.
-