HEATED OXYGEN SENSOR(for Sensor 1) INSPECTION
PROCEDURE
INSPECT HEATED OXYGEN SENSOR (Sensor 1)
-
*a
Component without harness connected
(Heated Oxygen Sensor (Sensor 1))
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 (+B) - 2 (HT1A)
20°C (68°F)
2.7 to 3.3 Ω
2 (HT1A) - 3 (E1)
Always
10 kΩ or higher
If the result is not as specified, replace the heated oxygen sensor (sensor 1).
-