VVT SENSOR INSTALLATION


  1. INSTALL VVT SENSOR (for Bank 2)


    1. A01E0ST

      Install the sensor with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Connect the sensor connector.

    3. A01DV3U

      Connect the No. 4 and No. 5 water by-pass hoses.

  2. INSTALL VVT SENSOR (for Bank 1)


    1. A01DXZT

      Install the sensor with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    2. Connect the sensor connector.

  3. REMOVE AIR CLEANER ASSEMBLY

    Torque:
    8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
  4. REMOVE NO. 2 VENTILATION HOSE

  5. ADD ENGINE COOLANT


    1. Tighten all the plugs and fill the radiator with TOYOTA Super Long Life Coolant (SLLC).

      Torque:
      13 N*m  { 130 kgf*cm, 9 ft.*lbf, for cylinder block drain cock plug }
      Standard capacity
      Item Specified Condition
      A/T 9.8 liters (10.4 US qts, 8.6 Imp. qts)
      M/T 8.5 liters (9.0 US qts, 7.5 Imp. qts)

      Tech Tips


      • TOYOTA vehicles are filled with TOYOTA SLLC at the factory. In order to avoid damage to the engine cooling system and other technical problems, only use TOYOTA SLLC or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic and technology consists of a combination of low phosphates and organic acids).

      • Please contact your TOYOTA dealer for further details.

      Note

      Never use water as a substitute for engine coolant.

    2. Press the inlet and outlet radiator hoses several times by hand, and then check the level of the coolant.

    3. Install the radiator cap.

    4. Bleed air from the cooling system.


      1. Warm up the engine until the thermostat opens. While the thermostat is open, circulate the coolant for several minutes.

      2. Maintain the engine speed at 2,000 to 2,500 rpm.

      3. Press the inlet and outlet radiator hoses several times by hand to bleed air.

        CAUTION:

        When pressing the radiator hoses:
        • Wear protective gloves.

        • Be careful as the radiator hoses are hot.

        • Keep your hands away from the radiator fan.

    5. Stop the engine and wait until the coolant cools down to ambient temperature.

      CAUTION:

      Do not remove the radiator cap while the engine and radiator are still hot. Pressurized, hot engine coolant and steam may be released and cause serious burns.

    6. A01DYUGE01

      Check the coolant level in the radiator reservoir.

      If the coolant level is low, add SLLC to the reservoir F line.

  6. CHECK FOR ENGINE COOLANT LEAKS


    1. Check for engine coolant leaks Click here.

  7. INSTALL V-BANK COVER


    1. Install the V-bank cover with the 2 nuts.

  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

  9. PERFORM INITIALIZATION


    1. Perform initialization Click here.

      Note

      Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.