STOP AND START SYSTEM DATA LIST / ACTIVE TEST

  1. DATA LIST

    Tip:

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note:

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    1. Warm up the engine.

    2. Turn the ignition switch off.

    3. Connect the GTS to the DLC3.

    4. Start the engine.

    5. Turn the GTS on.

    6. Enter the following menus: Powertrain / Stop and Start / Data List.

    7. According to the display on the GTS, read the Data List.

  2. ACTIVE TEST

    Tip:

    Using the GTS to perform Active Tests allows relays, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    1. Connect the GTS to the DLC3.

    2. Start the engine.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Active Test.

    5. Perform the Active Test by referring to the table below.

Powertrain > Stop and Start > Data List

Tester Display

Measurement Item

Range

Normal Condition

Diagnostic Note

Eco Warning

Stop and start indicator light status

ON/OFF

OFF: Stop and start indicator light off or on (not blinking) under normal system operation

ON: Any malfunction occurs in the system and the stop and start indicator light is blinking.

Coolant Temp

Engine coolant temperature

Min.: 16°C (60.8°F), Max.: 127°C (260.6°F)

75 to 95°C (167 to 203°F): Idling after engine warmed up

This is sent from the ECM.

Engine Spd (ECM)

Engine speed signal from ECM via CAN communication

Min.: 0 rpm, Max.: 12800 rpm

720 to 820 rpm: Idling after engine warmed up (for 1AD-FTV, 1ND-TV)

600 to 700 rpm: Idling after engine warmed up (for 1NR-FE)

This is sent from the ECM.

Engine Spd (NE Signal)

Engine speed signal from ECM via direct line

Min.: 0 rpm, Max.: 25599 rpm

720 to 820 rpm: Idling after engine warmed up (for 1AD-FTV, 1ND-TV)

600 to 700 rpm: Idling after engine warmed up (for 1NR-FE)

The pulse signal sent is from NEO terminal of the ECM.

Deceleration Sens Offset Val

Deceleration sensor offset value

Min.: -1176.008 m/s2, Max.: 1176.007 m/s2

-0.903 to 0.903 m/s2: After the deceleration sensor zero point learning completion

-

Deceleration Sens Calibration

Deceleration sensor calibration status

Incmpl / Running / Compl / Err1 / Err2 / Err3

Compl: After the deceleration sensor zero point learning completion

-

Gradient of Road Surface

Degree of road gradient

Min.: 0 m/s2, Max.: 20.4 m/s2

-1.4 to 1.4 m/s2: Vehicle is stopped on level surface

-

Battery Voltage

Battery voltage

Min.: 0 V, Max.: 20 V

8 to 14 V: Idling

-

Battery Voltage 2

VB voltage

Min.: 0 V, Max.: 65.53 V

8 to 14 V: Idling

-

Battery Fluid Temperature

Battery fluid temperature

Min.: -40°C (-40°F), Max.: 100°C (212°F)

Changes according to actual temperature: Driving after engine warmed up

-

Battery Temp (Start)

Battery temperature at engine start

Min.: -40°C (-40°F), Max.: 100°C (212°F)

Same as temperature around battery at engine start (after engine start)

-

Engine Type Information

Information on the engine type from the ECD or SFI system

Avail/Not Avi

Avail: Information of the engine type received from the ECM through CAN communication

Not Avi is displayed if improper engine type information is received from the ECM via CAN communication.

Starter Type

Starter assembly type

Other than Tandem Starter/Tandem Starter

Other than Tandem Starter

-

D Curtsey Switch Signal

Driver door courtesy switch signal

ON/OFF

ON: Driver side door opened

OFF: Driver side door closed

-

Hood Courtesy Switch

Hood courtesy switch signal

ON/OFF

ON: Engine hood closed

OFF: Engine hood opened

-

Neutral Switch

Neutral start switch assembly signal

ON/OFF

ON: Shift lever in neutral

OFF: Shift lever not in neutral

-

Clutch Upper SW

Clutch switch assembly signal

ON/OFF

ON: Clutch pedal fully released

OFF: Clutch pedal depressed

-

Clutch Lower SW

Clutch start switch assembly signal

ON/OFF

ON: Clutch pedal fully depressed

OFF: Clutch pedal released

-

Starter

Starter status

ON/OFF

ON: Cranking

OFF: Not cranking

-

TC Terminal

TC and CG terminals of DLC3

ON/OFF

ON: TC and CG terminals of DLC3 are connected

OFF: TC and CG terminals of DLC3 are disconnected

-

Cancel Switch

Stop and start cancel switch (ecorun cancel switch assembly) signal

ON/OFF

ON: Stop and start cancel switch (ecorun cancel switch assembly) pressed

OFF: Stop and start cancel switch (ecorun cancel switch assembly) not pressed

-

IG Switch

Ignition or starter switch assembly*1 or push start switch assembly*2 signal

ON/OFF

ON: Ignition switch ON

-

Idle

Engine idling status

ON/OFF

ON: Accelerator pedal fully released

OFF: Accelerator pedal depressed

This is sent from the ECM.

Engine Start (IG SW)

Engine start by ignition or starter switch assembly*1 or push start switch assembly*2 operation

ON/OFF

ON: Engine start by ignition or starter switch assembly*1 or push start switch assembly*2 operation

OFF: Except engine start by ignition or starter switch assembly*1 or push start switch assembly*2 operation

Indicates starter operation by operation of the ignition or starter switch assembly*1 or push start switch assembly*2

Stop Light SW (ECM)

Stop light switch assembly signal from ECM

ON/OFF

ON: Brake pedal depressed

OFF: Brake pedal released

This is sent from the ECM.

Stop Light SW (ABS/VSC)

Stop light switch assembly signal from brake system

ON/OFF

ON: Brake pedal depressed

OFF: Brake pedal released

This is sent from the skid control ECU (brake actuator assembly).

Fuel Heater Signal(ECD)

Combustion type power heater signal

ON/OFF

ON: Heater switch assembly on

OFF: Heater switch assembly off

-

Engine Starter Signal

Starter signal status

ON/OFF

ON: Cranking

OFF: Not cranking

This is sent from the ECM.

Buzzer

Buzzer status

ON/OFF

ON: Buzzer ON

OFF: Buzzer does not sound

Refer to warning buzzer operation conditions.

Indicat. Light Eco

Stop and start indicator light status

ON/OFF

ON: Stop and start indicator light on or blinking

OFF: Stop and start indicator light off

-

Oil Prs Warn Light Prohibit

Oil pressure warning light status

Permit/Prohibit

Prohibit: During engine stop by stop and start control

Permit: Not during engine stop by stop and start control

Engine stop and start ECU informs the combination meter assembly that the oil pressure warning light does not come on during engine stop by stop and start control. (for 1NR-FE)

S&S Cancel Light Code

Transmission code from the engine stop and start ECU to the combination meter assembly

0: extinction / 1: lighting / 2: blink / 3: - / 4: DTC output

0: Stop and start cancel indicator light off

1: Stop and start cancel indicator light on

Stop and start cancel indicator light on/blinking/off request sent to combination meter assembly.

Starter Operation #

Number of starter operations (count record)

Min.: 0, Max.: 1048575

-

-

Number of Engine Starts (IG-ON)

The number of starter operations by ignition or starter switch assembly*1 or push start switch assembly*2 operation

Min.: 0, Max.: 16777215

-

-

Number of Engine Starts (Stop & Start)

The number of starter operations by stop and start control

Min.: 0, Max.: 16777215

-

-

Number of Engine Starts (Clutch Released)

The number of starter operations without clutch pedal being depressed

Min.: 0, Max.: 16777215

-

-

Number of Engine Starts (Clutch Half-Depressed)

The number of starter operations with clutch pedal depressed halfway

Min.: 0, Max.: 16777215

-

-

Vehicle Spd1 (ABS/VSC)

Vehicle speed signal from skid control ECU via CAN communication

Min.: 0 km/h (0 mph), Max.: 327.67 km/h (203.6 mph)

0 km/h (0 mph): Vehicle is stopped

-

Battery Current

Battery current

Min.: 0 A, Max.: 124.99 A

-

-

Brake Boost Pressure

Brake booster pressure (absolute pressure)

Min.: 0 kPa (0 kgf/cm2, 0 psi), Max.: 112 kPa (1.1 kgf/cm2, 16 psi)

Approx. 100 kPa (1.0 kgf/cm2, 15 psi): Ignition switch ON, brake pedal depressed several times (differs according to atmospheric pressure)

-

Brake Negative Pressure

Brake booster vacuum (negative pressure)

Min.: 0 kPa (0 kgf/cm2, 0 psi), Max.: 639.98 kPa (6.53 kgf/cm2, 92.8 psi)

Approx. 0 kPa (0 kgf/cm2, 0 psi): Ignition switch ON, brake pedal depressed several times

This item cannot be checked if an error occurs in communication with the ECM.

Ambient Temp Sensor

Ambient temperature

Min.: -30°C (-22°F), Max.: 50°C (122°F)

Close to ambient temperature

-

Stop&Start of Eng State

Stop and start control status

IG / Run / Stopreq / Stop / Restart

  • IG: Before engine started

  • Run: Engine running

  • Stopreq: Engine stop requested

  • Stop: Engine stopped (by stop and start control)

  • Restart: Engine restarted

-

Idling Stop Rate

Rate of the idling stop time to the entire ignition switch ON time

Min.: 0%, Max.: 100%

-

-

Total Idling Stop Rate

Rate of idling stop time to the entire ignition switch ON time

Min.: 0%, Max.: 100%

-

-

Integrated Current

Battery integrated current

Min.: -268434.45 A-sec, Max.: 268435.45 A-sec

Differs according to the vehicle condition (charge/discharge conditions)

Refer to "Regarding Battery Integrated Current" below for details.*3

Cranking Time

Engine cranking time (in current trip) (When minimum voltage is detected at engine start)

Min.: 0 ms, Max.: 134215 ms

300 to 3000 ms: Duration of starter operation by stop and start control

-

Min Voltage(Cranking)

Minimum battery voltage while engine cranking (in current trip)

Min.: 0 V, Max.: 327.67 V

6 to 11 V

Lowest battery voltage measured in a 5 second period after the starter starts operating.

Min Volt(After Cranking)

Minimum battery voltage just after engine cranking

Min.: 0 V, Max.: 327.67 V

6 to 11 V

Minimum battery voltage while the starter operating

Status of Battery Charge Control

Battery charge control status

Change Control Condition Mode/Stop and Start Standalone/Refresh Charge Mode/Stp and Start Restriction Mode/Temperature High/Low Mode/Abnormal Mode/Battery Condition Judgment Mode/Low Temperature Mode

-

-

State of BBC

Backup boost converter status

Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset

Normal: Backup boost converter operating normally

  • Duty Err:

    • Abnormal duty ratio is detected.

  • Cycle Err:

    • Abnormal output voltage cycle is detected.

  • Low Vol:

    • A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.

  • Overload:

    • Overcurrent is detected.

  • Overvol:

    • When the ignition switch is ON:

      1. Overvoltage is detected at the control IC power source in the backup boost converter

      2. Overheating is detected at the control IC power source in the backup boost converter

    • When boosting:

      1. Error is detected in the feedback circuit in the backup boost converter

      2. Too high or low output voltage.

BBC Check Result

Backup boost converter check result

Normal/Abnormal

Normal: backup boost converter normal

Abnormal is displayed if excessive electrical load is applied to the converter at engine start.

State of External BBC

External backup boost converter status

Cycle Err/Overvol/Overload/Normal/Low Vol/Duty Err/Low Temp

-

-

External BBC Malfunction History

External backup boost converter malfunction history

No/Yes

-

-

External BBC Overcurrent History

External backup boost converter overcurrent history

No/Yes

-

-

Atmosphere Pressure

Atmospheric pressure (calculated value)

Min.: 0 kPa (0 kgf/cm2, 0 psi), Max.: 255 kPa (2.6 kgf/cm2, 37 psi)

Approx. 100 kPa (1.0 kgf/cm2, 15 psi): Ignition switch ON (close to actual atmospheric pressure)

ECM calculated value

EPS Load

Electric power steering current

Min.: -327.68 A, Max.: 327.67 A

Approx. 0 A: EPS assist is not activated

-

Accelerator Position

Accelerator pedal position

Min.: 0%, Max.: 127.5%

Actual accelerator pedal position

-

Engine OFF Request

Engine stop request

ON/OFF

ON: Engine stopped due to stop and start control

OFF: Not during engine stop by stop and start control

ON is displayed when fuel-cut is performed by stop and start control, engine start is not requested, or starter is forced to operate.

Manual Start during S&S

Manual start during stop and start control operation

ON/OFF

-

-

Wrong Operation (Start)

Wrong operation for engine start

ON/OFF

OFF

Unused

Engine Reverse Rev.

Engine reverse revolution status

ON/OFF

-

-

N/Clutch Lower SW Abnoml

Clutch start switch assembly (for lower)

ON/OFF

-

-

N/Clutch Upper SW Abnoml

Clutch switch assembly (for upper)

ON/OFF

-

-

Permit Idling Stop

Engine stop standby

ON/OFF

-

-

Running History

Vehicle driving record

ON/OFF

ON: History of driving vehicle at 2 km/h (1 mph) or more (without DTC output)

Turns OFF when the engine is stopped by stop and start control.

Simple-IPA Available

Availability of Simple-IPA on vehicle

No/Yes

-

-

Auto A/C

Availability of air conditioning system on vehicle

Without/With

With: Equipped with air conditioning system

Without: Not equipped without air conditioning system

Air conditioning information needs to be registered after engine stop and start ECU replacement.

Eng Start Req (A/C 2)

Engine start request from the air conditioning system

ON/OFF

ON: Engine start requested to ensure air conditioning system performance

OFF: Engine start not requested to ensure air conditioning system performance

-

Wheel Speed Malfunction

Wheel speed sensor malfunction status

ON/OFF

OFF: Input value from speed sensor is normal

ON remains displayed when any input values from the wheel speed sensors are abnormal.

E/G ECU Region Mismatch

ECM region mismatch status

ON/OFF

OFF: Engine ECU destination information is matched.

ON remains displayed when the engine ECU for regions destinations without the stop and start system settings is detected.

Oper Permission (Neutral Switch)

Permission of stop and start control based on the neutral position switch conditions

NG/OK

OK: Shift lever in neutral

-

Oper Permission (Idling)

Permission of stop and start control based on the engine idle conditions

NG/OK

OK: Engine idling (engine speed below 1250 rpm) without accelerator pedal being depressed

-

Oper Permission (Vehicle Speed)

Permission of stop and start control based on the vehicle speed conditions

NG/OK

OK: Vehicle is stopped

OK is displayed while vehicle is stopped.

Stop&Start Precondition

Permission of stop and start control with all preconditions met

ON/OFF

ON: Preconditions for stop and start control have been met

Condition of permission or prohibition for terms listed below.

(ECM1, ECM2, idling, battery, ABS/VSC2, IGSW, DTC, A/C, interval, after running, engine hood closed, D door closed, cancel switch, steering, interval for starter, key operation, driver side buckle SW, ambient temperature)

For details on the preconditions, refer to System Description.

Stop&Start Precondition 2

Permission of stop and start control with all preconditions met

ON/OFF

ON: Preconditions for stop and start control have been met

Condition of permission or prohibition for terms listed below.

(Brake negative pressure, starter check complete)

Oper Permission (ECM 1)

Permission of stop and start control by the ECM

NG/OK

OK: Stop and start control is enabled (ECD or SFI system is normal)

-

Oper Permission (ECM 2)

Permission of stop and start control by ECD or SFI system

NG/OK

OK: Stop and start control is enabled (ECD or SFI system is normal)

This is sent from the ECM through CAN communication

Oper Permission (IG SW)

Permission of stop and start control based on the ignition or starter switch assembly*1 or push start switch assembly*2 conditions

NG/OK

OK: Ignition switch ON for 5 seconds

-

Oper Permission (DTC)

Permission of stop and start control based on the DTC output conditions

NG/OK

OK: DTC is not output

-

Oper Permission (Brake Negative Pressure)

Permission of stop and start control based on the brake booster vacuum conditions

NG/OK

OK: Brake booster vacuum approx. 45 kPa (0.5 kgf/cm2, 7 psi) or more (threshold varies by road gradient)

-

Oper Permission (Interval)

Permission of stop and start control based on the engine running time conditions

NG/OK

OK: A certain period of time has elapsed after starter operation

-

Oper Permission (D Door Closed)

Permission of stop and start control based on the driver door open/close conditions

NG/OK

OK: Driver door closed

-

Oper Permission (Engine Hood Closed)

Permission of stop and start control based on the engine hood open/close conditions

NG/OK

OK: Engine hood closed

-

Oper Permission (A/C)

Permission of stop and start control based on the air conditioning conditions

NG/OK

OK: Air conditioning conditions are met

-

Oper Permission (Ambient Temperature)

Permission of stop and start control based on the air conditioning conditions

NG/OK

OK: Ambient temperature -5°C (23°F) or higher

-

Oper Permission (After Running)

Permission of stop and start control based on the initial trip conditions after the ignition switch is turned ON

NG/OK

OK: Vehicle has been driven at 7 km/h (4 mph) or more

OK is displayed after the initial trip until the ignition switch is turned off.

Oper Permission (Neutral SW OFF History)

Permission of stop and start control based on the shift operation history

NG/OK

OK: Neutral position switch OFF record is detected (remains ON until next stop and start system control)

-

Oper Permission (Clutch Upper SW OFF History)

Permission of stop and start control based on the clutch pedal operation history

NG/OK

OK: Clutch pedal depressed

-

Oper Permission (Battery)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed

-

Oper Permission (Start Min Volt 1)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage at starter ON is the threshold value or higher

If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

Oper Permission (Start Min Volt 2)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher

If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

Oper Permission (Start Min Volt 3)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage right after engine cranking is the threshold value or higher

If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

Oper Permission (Start Min Volt 4)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher

If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

Oper Permission (Battery Current)

Permission of stop and start control based on the battery conditions

NG/OK

OK: Battery discharge current is -125 A or less

Engine stop and start ECU calculated value

Oper Permission (Integrated Current)

Permission of stop and start control based on the integrated current value conditions

NG/OK

OK: Integrated current value is more than specified

The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.

Refer to "Regarding Battery Integrated Current" below for details.*3

Oper Prohibition (Jump Start)

Prohibition of stop and start control based on the jump start conditions

Permit/Prohibit

Prohibit: Engine started by ignition switch operation with the engine hood open

When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

Oper Prohibition (Manual Start)

Prohibition of stop and start control based on the manual start conditions

Permit/Prohibit

Prohibit: During manual start

When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

Conditions for Manual Start:

  • Clutch start switch OFF or vehicle speed signal input

  • Neutral position switch OFF

  • Starter signal OFF

Oper Permission (Interval For Starter)

Permission of stop and start control based on the conditions after engine restart

NG/OK

OK: A maximum of 4 minutes have elapsed after engine restarted

-

Oper Permission (Cancel Switch)

Permission of stop and start control based on the stop and start cancel switch (ecorun cancel switch assembly) operation

NG/OK

OK: Stop and start control is permitted (the stop and start cancel indicator light is not illuminated)

-

Oper Permission (ABS/VSC 2)

Permission of stop and start control by the anti-lock brake system

NG/OK

OK: Brake control not operating

-

Oper Permission (Road Surface Gradient)

Permission of stop and start control based on the road grade conditions

NG/OK

-

Unused

Oper Permission (Driver Side Buckle SW)

Permission of stop and start control based on the driver seat belt condition

NG/OK

OK: The driver side buckle switch is fastened

-

Oper Permission (Steering)

Permission of stop and start control by the power steering ECU assembly

NG/OK

OK: EPS system is normal operated

-

Oper Permission (Key Operation)

Permission of stop and start control based on the ignition or starter switch assembly*1 or push start switch assembly*2 operation

NG/OK

OK: Ignition or starter switch assembly*1 or push start switch assembly*2 not operated

-

Oper Permission (Starter Check Complete)

Permission of stop and start control based on the starter circuit self-check result

NG/OK

OK: Stop and start control enabled (starter circuit normal)

When the engine stop and start ECU is abnormal, the starter drive circuit is judged to be abnormal, and NG is displayed

Oper Permission (Simple-IPA Button)

Permission of stop and start control based on the Simple-IPA button operation

NG/OK

OK: Stop and start control enabled (Simple-IPA not operating)

-

Oper Prohibition (Engine F/C)

Prohibition of stop and start control based on the engine fuel-cut prohibition signal

Permit/Prohibit

Prohibit: Fuel-cut not performed on ECD or SFI system

-

Eng Start Req (Brk Negative Pressure Low)

Engine start request due to low brake booster vacuum

ON/OFF

ON: Brake booster vacuum insufficient while engine stopped by stop and start control

  • OFF is usually displayed

  • ON is displayed when the engine is started due to decreased brake booster vacuum caused by depressing the brake pedal several times

Eng Start Req (IG Switch)

Engine start request due to ignition or starter switch assembly*1 or push start switch assembly*2 operation

ON/OFF

ON: Engine started using ignition or starter switch assembly*1 or push start switch assembly*2 while engine stopped by stop and start control

-

Eng Start Req (ECM)

Engine start request from ECM

ON/OFF

ON: Engine start requested by ECM

-

Eng Start Req (A/C)

Engine start request from Air conditioning system

ON/OFF

ON: Engine start requested by air conditioning system

-

Eng Start Req (Steering)

Engine start request by the power steering system

ON/OFF

ON: Power steering assist current is abnormal

-

Eng Start Req (Detect DTC)

Engine start request due to output of DTCs

ON/OFF

ON: Engine start requested due to output of stop and start system DTCs

-

Eng Start Req (Clutch Pedal)

Engine start request by the clutch pedal

ON/OFF

ON: Clutch pedal is depressed

-

Eng Start Req (Clutch Lower SW)

Engine start request by the clutch start switch assembly (for lower)

ON/OFF

ON: Clutch pedal is fully depressed

-

Eng Start Req (Engine Hood Open)

Engine start request due to opening of engine hood

ON/OFF

ON: Engine hood open (with shift lever in neutral) while the engine is stopped by stop and start control

-

Eng Start Req (Battery Condition)

Engine start request based on battery performance

ON/OFF

ON: Engine start requested due to low battery voltage while the engine is stopped by stop and start control

-

Eng Start Req (CVT Vehicle Speed)

Engine start request based on vehicle speed signal from the CVT system

ON/OFF

OFF

Unused

Eng Start Req (ABS Vehicle Speed)

Engine start request based on vehicle speed signal from the brake system

ON/OFF

ON: Engine start requested due to speed signal while the engine is stopped by stop and start

Engine start request based on the speed sensor signal

Eng Start Req(Cancel SW)

Engine start request by stop and start system cancel switch

ON/OFF

ON: Engine start requested due to stop and start cancel switch (ecorun cancel switch assembly) operation while the engine is stopped by stop and start control

-

Eng Start Req (Simple-IPA)

Engine start request due to the Simple-IPA button operation

ON/OFF

ON: Engine start requested due to operation of Simple-IPA button

-

Eng Start Req(Courtesy SW or Buckle SW)

Engine start request by courtesy switch (driver side) or driver side buckle switch

ON/OFF

ON: Engine start requested due to courtesy switch (for driver side) or driver side buckle switch operation while the engine is stopped by stop and start control

-

ABS Running

Operating condition of the anti-lock brake system

ON/OFF

ON: Anti-lock brake system operating

-

N Position Switch

Neutral position switch status

OK/NG

OK: System normal

-

Alternator Status

Alternator power generation status

Normal/Abnormal

Normal: Alternator operation normal

-

EEPROM

Error in EEPROM

Normal/Abnormal

Normal: EEPROM normal

-

Dec Sensor Calibration

Deceleration sensor zero point uncalibrated

Comp/Incomp

Comp: Deceleration sensor learning completed

-

Deceleration Sensor Movement

Sticking of the deceleration sensor

Normal/Abnormal

Normal: Deceleration sensor not stuck

-

Engine Stall History during S&S (Hood Open)

History of engine stall caused by depressing the clutch pedal with the engine hood open while the engine is stopped by stop and start control (shift lever in neutral)

No/Yes

No: No history

-

Engine Stall History during S&S (Collision or Battery Voltage Low)

History of engine stall due to a collision or low battery voltage when the stop and start control is operating

No/Yes

No: No history

-

Engine Stall History during Engine Starting (Collision)

History of engine stall due to a collision while the engine is stopped by stop and start control

No/Yes

No: No history

-

Engine Start Fail

History of engine restart failure by stop and start control

No/Yes

No: No history

-

NE Sensor Circuit Open2

Malfunction in the crank position sensor circuit

ON/OFF

OFF: System is normal

ON: No engine speed input at engine start.

Brk Boost Malfunc 1

Fail-safe operation due to malfunction in the vacuum sensor assembly

OK/NG

OK: System is normal

Fail-safe operation due to sticking of the vacuum sensor assembly (a change in the sensor value is small when STP signal changes from ON to OFF)

Brk Boost Malfunc 2

Fail-safe operation due to malfunction in the vacuum sensor assembly

OK/NG

OK: System is normal

Fail-safe operation due to sticking of the vacuum sensor assembly (a change in the sensor value is small, even though the vehicle speed has increased from 0 km/h (0 mph) to 30 km/h (18.6 mph) 30 times)

N Position Voltage Status

Malfunction in the neutral position switch

Normal/Hi/Low

Normal: Neutral position switch voltage normal

-

Num of Current Code

Number of currently stored DTCs

Min.: 0, Max.: 255

-

-

Number of Oper Prohibition (ECM 1)

Number of stop and start control prohibitions when ECM conditions are not met

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (ECM 2)

Number of stop and start control prohibitions due to ECD or SFI system

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Engine F/C)

Number of stop and start control prohibitions due to fuel-cut

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Jump Start)

Number of stop and start control prohibitions due to jump start

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Engine Hood Closed)

Number of stop and start control prohibitions due to open engine hood

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Possible Clutch Lower SW Abnormality)

Number of stop and start control prohibitions due to clutch start switch assembly (for lower) malfunction

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Possible Clutch Upper SW Abnormality)

Number of stop and start control prohibitions due to clutch start switch assembly (for upper) malfunction

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Neutral SW OFF History)

Number of stop and start control prohibitions due to neutral start switch

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Clutch Upper SW OFF History)

Number of stop and start control prohibitions due to clutch start switch assembly (for upper)

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Battery)

Number of stop and start control prohibitions due to battery condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Start Min Volt)

Number of stop and start control prohibitions due to battery condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Battery Current)

Number of stop and start control prohibitions due to battery condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Integrated Current)

Number of stop and start control prohibitions due to battery condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (A/C)

Number of stop and start control prohibitions due to air conditioning condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Ambient Temperature)

Number of stop and start control prohibitions due to ambient temperature condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (ABS/VSC 2)

Number of stop and start control prohibitions due to anti-lock brake system condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (ABS Running)

Number of stop and start control prohibitions due to anti-lock brake system operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Brake Negative Pressure)

Number of stop and start control prohibitions due to brake negative pressure condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Stop&Start Precondition1)

Number of stop and start control prohibitions due to precondition 1

Min.: 0, Max.: 4294967295

-

Condition of permission or prohibition for terms listed below.

(ECM1, ECM2, idling, battery, ABS/VSC2, IGSW, DTC, A/C, interval, after running, engine hood closed, D door closed, cancel switch, steering, interval for starter, key operation, driver side buckle SW, ambient temperature)

For details on the preconditions, refer to System Description.

Number of Oper Prohibition (Stop&Start Precondition2)

Number of stop and start control prohibitions due to precondition 2

Min.: 0, Max.: 4294967295

-

Condition of permission or prohibition for terms listed below.

(Brake negative pressure, starter check complete)

Number of Oper Prohibition (DTC)

Number of stop and start control prohibitions due to DTC output

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Abnormal Wheel Speed Sensor Inputs)

Number of stop and start control prohibitions due to abnormal vehicle speed signal input

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Deceleration Sensor Abnormal)

Number of stop and start control prohibitions due to deceleration sensor malfunction

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Interval For Starter)

Number of stop and start control prohibitions due to starter fail-safe operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Interval)

Number of stop and start control prohibitions due to periodic control prohibition after engine stop

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Cancel Switch)

Number of stop and start control prohibitions due to stop and start cancel switch (ecorun cancel switch assembly) operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Simple-IPA Button)

Number of stop and start control prohibitions due to simple-IPA button operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Driver Side Buckle SW)

Number of stop and start control prohibitions due to unfastened driver seat belt

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (D Door Closed)

Number of stop and start control prohibitions due to open driver door

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (IG SW)

Number of stop and start control prohibitions due to Ignition or starter switch assembly*1 or push start switch assembly*2 operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (After Running)

Number of stop and start control prohibitions based on the initial trip conditions

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Manual Start)

Number of stop and start control prohibitions due to manual start condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Manual Start during S&S)

Number of stop and start control prohibitions due to manual start condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Idling)

Number of stop and start control prohibitions due to idling condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Road Surface Gradient)

Number of stop and start control prohibitions due to road surface gradient condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Steering)

Number of stop and start control prohibitions due to power steering system condition

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Key Operation)

Number of stop and start control prohibitions due to Ignition or starter switch assembly*1 or push start switch assembly*2 operation

Min.: 0, Max.: 4294967295

-

-

Number of Oper Prohibition (Starter Check Complete)

Number of stop and start control prohibitions due to incomplete starter circuit check

Min.: 0, Max.: 4294967295

-

-

Number of Eng Start Req (ECM)

Number of engine start requests from ECD or SFI system

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Engine Hood Open)

Number of engine start requests due to opening of engine hood while engine is stopped by stop and start control

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Clutch Lower SW)

Number of engine start requests from clutch start switch assembly (for lower)

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Battery Condition)

Number of engine start requests due to low battery performance

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (A/C)

Number of engine start requests from air conditioning system

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Brk Negative Pressure Low)

Number of engine start requests due to low brake booster vacuum

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Detect DTC)

Number of engine start requests due to DTC output

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (CVT Vehicle Speed)

Number of engine start requests due to CVT vehicle speed signal input

Min.: 0, Max.: 65535

-

Unused

Number of Eng Start Req (ABS Vehicle Speed)

Number of engine start requests due to anti-lock brake system vehicle speed signal input

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Cancel SW)

Number of engine start requests due to stop and start cancel switch (ecorun cancel switch assembly) operation

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Simple-IPA)

Number of engine start requests due to simple-IPA operation

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Courtesy SW or Buckle SW)

Number of engine start requests due to driver exiting vehicle

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (IG Switch)

Number of engine start requests due to Ignition or starter switch assembly*1 or push start switch assembly*2 operation

Min.: 0, Max.: 65535

-

-

Number of Eng Start Req (Steering)

Number of engine start requests due to steering operation

Min.: 0, Max.: 65535

-

-

  • *1: w/o Entry and Start System

  • *2: w/ Entry and Start System

*3: Regarding Battery Integrated Current

In the stop and start system, the engine stop and start ECU switches the system control mode (stop and start control permitted/prohibited) based on the battery condition (charge/discharge condition) to protect the battery and to ensure stable engine restarting performance.

The battery charge-discharge condition is determined from the integrated current value calculated from the battery current sensor (generator control ECU assembly) signal. The integrated current value is obtained by multiplying the current (Ampere) detected from the battery current sensor (generator control ECU assembly) by the time (seconds), and it is expressed in a unit A-sec.

Example: Integrated current of -3110 A-sec corresponds to a load where current of 10 A flows out from the battery for 311 seconds.

Using the Data List function of the GTS, the integrated current value can be read by checking the Data List item "Integrated Current". The item "Battery Integrated Current" shows the permission status of stop and start control (ON or OFF) and is judged from the "Integrated Current" value.

Negative integrated current represents battery discharge, and positive represents battery charge. In other words, the "Integrated Current" value of the Data List item will decrease from the present value when the battery is discharged, and the value will increase when the battery is charged.

The engine stop and start ECU determines the amount of power available based on the integrated current value, and it prohibits stop and start control if the value is below the threshold, because the battery might not be able to start the engine. The threshold varies according to the battery temperature.

Furthermore, the integrated current value is recorded inside the engine stop and start ECU memory even if the ignition switch is off, and when the ignition switch is next turned to ON, the value is calculated from the value recorded when the ignition switch was turned off.

Integrated Current Condition 1 (for 1AD-FTV):

The battery charge is sufficient and the battery temperature is -1°C (30.2°F) or higher and below 70°C (158°F):

A217716E07
  • Stop and Start System Operation (for Condition 1)

  • Phase A:

    When the ignition switch is turned off, the integrated current value is recorded in the ECU memory. The value is carried over to the next trip.

  • Phase B:

    After the engine is started using the ignition switch, stop and start control is prohibited until the integrated current reaches 0 A-sec once. (The battery is being charged during this phase.)

  • Phase C:

    Stop and start control is permitted until the integrated current value decreases to -6451 A-sec.

  • Phase D:

    After the integrated current value decreases below -6451 A-sec, stop and start control is prohibited until the value increases to -5299 A-sec or higher again. (The battery is being charged during this phase.)

  • Phase E:

    Stop and start control is permitted. After this, system control is permitted until the integrated current value decreases below-6451 A-sec.

Integrated Current Condition 1 (for 1ND-TV, 1NR-FE):

The battery charge is sufficient and the battery temperature is -1°C (30.2°F) or higher and below 70°C (158°F):

A217716E09
  • Stop and Start System Operation (for Condition 1)

  • Phase A:

    When the ignition switch is turned off, the integrated current value is recorded in the ECU memory. The value is carried over to the next trip.

  • Phase B:

    After the engine is started using the ignition switch, stop and start control is prohibited until the integrated current reaches 0 A-sec once. (The battery is being charged during this phase.)

  • Phase C:

    Stop and start control is permitted until the integrated current value decreases to -4838 A-sec.

  • Phase D:

    After the integrated current value decreases below -4838 A-sec, stop and start control is prohibited until the value increases to -3974 A-sec or higher again. (The battery is being charged during this phase.)

  • Phase E:

    Stop and start control is permitted. After this, system control is permitted until the integrated current value decreases below-4838 A-sec.

Integrated Current Condition 2 (for 1AD-FTV):

The battery charge is insufficient or the battery temperature is below -1°C (30.2°F) or 70°C (158°F) or higher:

A217717E06
  • Stop and Start System Operation (for Condition 2)

  • Phase A:

    When the ignition switch is turned off, the integrated current value is recorded in the ECU memory. The value is carried over to the next trip.

  • Phase B:

    After the engine is started using the ignition switch, stop and start control is prohibited until the integrated current reaches 0 A-sec once. (The battery is being charged during this phase.)

  • Phase C:

    Stop and start control is permitted until the integrated current value decreases to -1152 A-sec.

  • Phase D:

    After the integrated current value decreases below -1152 A-sec, stop and start control is prohibited until the value increase to 0 A-sec or higher again. (The battery is being charged during this phase.)

  • Phase E:

    Stop and start control is permitted.

Integrated Current Condition 2 (for 1ND-TV, 1NR-FE):

The battery charge is insufficient or the battery temperature is below -1°C (30.2°F) or 70°C (158°F) or higher:

A217717E08
  • Stop and Start System Operation (for Condition 2)

  • Phase A:

    When the ignition switch is turned off, the integrated current value is recorded in the ECU memory. The value is carried over to the next trip.

  • Phase B:

    After the engine is started using the ignition switch, stop and start control is prohibited until the integrated current reaches 0 A-sec once. (The battery is being charged during this phase.)

  • Phase C:

    Stop and start control is permitted until the integrated current value decreases to -864 A-sec.

  • Phase D:

    After the integrated current value decreases below -864 A-sec, stop and start control is prohibited until the value increase to 0 A-sec or higher again. (The battery is being charged during this phase.)

  • Phase E:

    Stop and start control is permitted.

Tip:
  • The low battery temperature condition is detected when the battery temperature is less than 10°C (50°F). When the battery temperature becomes 11°C (51.8°F) or higher, the low battery temperature condition is cleared.

  • Performance (internal resistance) of lead-acid batteries used in typical vehicles changes according to the battery temperature. The internal resistance of the battery tends to be higher when the battery temperature is low. Thus, the stop and start system switches the threshold for determining the power charge according to the battery temperature when performing stop and start control.

  • If the battery is deteriorated, the internal resistance has also increased and the stop and start rate becomes lower. (The total of idling time while the vehicle is stopped increases.)

  • When troubleshooting, if the malfunction cannot be identified, the battery might be deteriorated.

Tip:

Even if stop and start control is prohibited due to the condition of any of the systems listed above, performing the Active Tests allows stop and start control to be performed.

Powertrain > Stop and Start > Active Test

Tester Display

Measurement Item

Control Range

Diagnostic Note

Buzzer

Buzzer activation

ON/OFF

-

Starter

Starter activation

ON/OFF

-

Permit Cond (A/C)

When stop by stop and start control is prohibited, prohibition of control based on the air conditioning conditions can be disabled/enabled.

ON/OFF

-

Permit Cond (Battery)

When stop by stop and start control is prohibited, prohibition of control based on the battery conditions can be disabled/enabled.

ON/OFF

-

Permit Cond (Engine)

When stop by stop and start control is prohibited, prohibition of control based on the ECD or SFI system conditions can be disabled/enabled.

ON/OFF

-

Precondition (Control)

Stop and start control can be permitted/prohibited based on precondition 1

ON/OFF

Condition of permission or prohibition for terms listed below.

(ECM1, ECM2, idling, battery, ABS/VSC2, IGSW, DTC, A/C, interval, after running, engine hood closed, D door closed, cancel switch, steering, interval for starter, key operation, driver side buckle SW, ambient temperature)

Precondition2 (Control)

Stop and start control can be permitted/prohibited based on precondition 2

ON/OFF

Condition of permission or prohibition for terms listed below.

(Brake negative pressure, starter check complete)

Start Cond (Hood Crtsy)

When engine stop by stop and start control is prohibited, prohibition of control based on the engine hood conditions can be disabled/enabled

ON/OFF

-