GENERATOR REMOVAL
PROCEDURE
PRECAUTION
Note:After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.
REMOVE V-RIBBED BELT
REMOVE GENERATOR ASSEMBLY
-
Remove the terminal cap.
Remove the nut and disconnect the wire harness from terminal B.
Disconnect the generator assembly connector.
Disengage the wire harness clamp.
Remove the bolt and 2 nuts.
-
Using an E8 "TORX" socket wrench, remove the stud bolt.
Remove the generator assembly.
-
Remove the bolt and wire harness clamp bracket from the generator assembly.
-