COMPRESSOR(for 2WW) REMOVAL
PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
REMOVE RADIATOR ASSEMBLY
REMOVE V-RIBBED BELT
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
-
Remove the bolt and disconnect the suction hose sub-assembly.
Remove the O-ring from the suction hose sub-assembly.
Note:Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
-
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
-
Remove the bolt and disconnect the discharge hose sub-assembly.
Remove the O-ring from the discharge hose sub-assembly.
Note:Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
-
REMOVE COMPRESSOR ASSEMBLY WITH PULLEY
-
Disconnect the connector.
Detach the clamp and disconnect the wire harness.
Remove the bolt and 2 nuts.
-
Using an E8 "TORX" socket wrench, remove the 2 stud bolts and compressor assembly with pulley.
Remove the compressor pin.
Note:It is not necessary to remove a compressor pin unless it being replaced.
-