POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH


    1. A005F3UE18
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Counterclockwise
      *c Clockwise

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      Motor gear rotates clockwise

      1. Connect the positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the power window regulator motor assembly LH.

      Note

      Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.

  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH


    1. A005C1NE17
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Counterclockwise
      *c Clockwise

      Apply positive (+) auxiliary battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) auxiliary battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect the positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 10 (UP).

      Motor gear rotates counterclockwise

      1. Connect a positive (+) auxiliary battery lead to terminal 2 (B), connect a negative (-) auxiliary battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) auxiliary battery lead to terminal 7 (DOWN).

      Motor gear rotates clockwise

      • If the result is not as specified, replace the power window regulator motor assembly RH.

      Note

      Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.