GENERATOR INSTALLATION
PROCEDURE
INSTALL GENERATOR ASSEMBLY
-
Install the generator assembly with the 3 bolts.
25 N*m
255 kgf*cm
18 ft.*lbf
Note:Make sure that the wire harness of the crankshaft position sensor does not get caught between the cylinder block and the generator when installing the generator assembly.
-
Connect the wire harness to terminal B and install the nut and bolt.
Nut
9.8 N*m
100 kgf*cm
87 in.*lbf
Bolt
8.4 N*m
86 kgf*cm
74 in.*lbf
Connect the connector.
Install the terminal cap.
-
INSTALL V-RIBBED BELT
INSTALL FRONT DRIVE SHAFT ASSEMBLY RH
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note:When disconnecting the cable, some systems need to be initialized after the cable is reconnected.