AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) IG Power Source Circuit

DTC Code DTC Name
IG Power Source Circuit

DESCRIPTION

The main power source is supplied to the air conditioning amplifier assembly when the ignition switch is ON.

The power is used for operating the air conditioning amplifier assembly, servo motors, etc.

WIRING DIAGRAM

E269935E02

CAUTION / NOTICE / HINT

Note:

Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE

  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BATTERY)

    1. E269948C03

      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection

      Switch Condition

      Specified Condition

      G81-1 (IG+) - Body ground

      Ignition switch off

      Below 1 V

      G81-1 (IG+) - Body ground

      Ignition switch ON

      11 to 14 V

    Result

    Proceed to

    OK

    NG

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR

    OK
  2. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)

    1. E269948C05

      *a

      Rear view of wire harness connector

      (to Air Conditioning Amplifier Assembly)

      Disconnect the air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      G81-14 (GND) - Body ground

      Always

      Below 1 Ω

    Result

    Proceed to

    OK

    NG

    OK

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

    NG

    REPAIR OR REPLACE HARNESS OR CONNECTOR