AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System), Diagnostic DTC:B1413/13
| DTC Code | DTC Name |
|---|---|
| B1413/13 | Evaporator Temperature Sensor Circuit |
DESCRIPTION
The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
DTC Code |
DTC Detection Condition |
Trouble Area |
|---|---|---|
B1413/13 |
An open or short in the No. 1 cooler thermistor circuit. |
|
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER
Use the Data List to check if the No. 1 cooler thermistor is functioning properly.
Table 1. Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Evaporator Fin Thermistor
No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed
Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).
OK
The display is as specified in the normal condition column.
Table 2. Result Result
Proceed to
OK (When troubleshooting according to Problem Symptoms Table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
INSPECT NO. 1 COOLER THERMISTOR
Remove the No. 1 cooler thermistor (Click here).
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.30 to 9.10 kΩ
-5°C (23°F)
5.65 to 6.95 kΩ
0°C (32°F)
4.40 to 5.35 kΩ
5°C (41°F)
3.40 to 4.15 kΩ
10°C (50°F)
2.70 to 3.25 kΩ
15°C (59°F)
2.14 to 2.58 kΩ
20°C (68°F)
1.71 to 2.05 kΩ
25°C (77°F)
1.38 to 1.64 kΩ
30°C (86°F)
1.11 to 1.32 kΩ
Note:Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
Tip:As the temperature increases, the resistance decreases (refer to the graph).
CHECK AIR CONDITIONING HARNESS ASSEMBLY
-
Remove the air conditioning harness assembly.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
z19-6 (TEA) - 1
Always
Below 1 Ω
z19-5 (SGA) - 2
Always
Below 1 Ω
z19-6 (TEA) - Body ground
Always
10 kΩ or higher
z19-5 (SGA) - Body ground
Always
10 kΩ or higher
Table 3. Text in Illustration *1
Front view of wire harness connector
(to No. 1 Cooler Thermistor)
*2
Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)
-