AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST

  1. DATA LIST

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note:

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Body Electrical > Air Conditioner > Data List

      Tester Display

      Measurement Item

      Range

      Normal Condition

      Diagnostic Note

      Room Temperature Sensor

      Cooler (room temperature sensor) thermistor

      Min.: -6.50°C (-20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual ambient temperature displayed

      -

      Ambient Temp Sensor

      Cooler (ambient temperature sensor) thermistor

      Min.: -23.30°C (-9.94°F)

      Max.: 65.95°C (150.71°F)

      Actual ambient temperature displayed

      -

      Adjusted Ambient Temp

      Adjusted ambient temperature

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      -

      -

      Evaporator Fin Thermistor

      No. 1 cooler thermistor (evaporator temperature sensor)

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed

      -

      Evaporator Target Temp

      Evaporator target temperature

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed

      -

      Solar Sensor (D Side)

      Driver side automatic light control sensor

      Min.: 0

      Max.: 255

      Driver side automatic light control sensor value increases as brightness increases

      -

      Solar Sensor (P Side)

      Front passenger side automatic light control sensor

      Min.: 0

      Max.: 255

      Front passenger side automatic light control sensor value increases as brightness increases

      -

      Engine Coolant Temp

      Engine coolant temperature sensor

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed

      -

      Set Temperature (D Side)

      Driver side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature displayed

      -

      Set Temperature (P Side)

      Front passenger side set temperature

      Min.: MAX COLD

      Max.: MAX HOT

      Front passenger side set temperature displayed

      -

      Blower Motor Speed Level

      Blower motor speed level

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases

      -

      Regulator Pressure Sensor

      Air conditioner pressure sensor

      Min.: -0.4566 MPaG

      Max.: 3.2943 MPaG

      Actual pressure displayed

      -

      Regulator Control Current

      Solenoid valve control current

      Min.: 0 A

      Max.: 0.997 A

      Value changes between 0 A and 0.997 A in accordance with solenoid valve operation

      -

      Air Mix Servo Targ Pulse(D)

      No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse

      Min.: 0

      Max.: 255

      for LHD:

      MAX. COLD: 92 (pulse)

      MAX. HOT: 5 (pulse)

      for RHD:

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      -

      Air Mix Servo Actual Pulse(D)

      No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse

      Min.: 0

      Max.: 255

      for LHD:

      MAX. COLD: 92 (pulse)

      MAX. HOT: 5 (pulse)

      for RHD:

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      -

      Air Mix Servo Targ Pulse(P)

      No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse

      Min.: 0

      Max.: 255

      for LHD:

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      for RHD:

      MAX. COLD: 92 (pulse)

      MAX. HOT: 5 (pulse)

      -

      Air Mix Servo Actual Pulse(P)

      No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse

      Min.: 0

      Max.: 255

      for LHD:

      MAX. COLD: 6 (pulse)

      MAX. HOT: 93 (pulse)

      for RHD:

      MAX. COLD: 92 (pulse)

      MAX. HOT: 5 (pulse)

      -

      Air Outlet Servo Pulse (D)

      No. 1 air conditioning radiator damper servo sub-assembly (mode) target pulse

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 17 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -

      Air Outlet Servo Actu Pulse(D)

      No. 1 air conditioning radiator damper servo sub-assembly (mode) actual pulse

      Min.: 0

      Max.: 255

      FACE: 47 (pulse)

      B/L: 37 (pulse)

      FOOT: 17 (pulse)

      FOOT/DEF: 9 (pulse)

      DEF: 5 (pulse)

      -

      Air Inlet Damper Targ Pulse

      No. 1 blower damper servo sub-assembly (air inlet) target pulse

      Min.: 0

      Max.: 255

      for LHD:

      RECIRCULATION: 19 (pulse)

      FRESH: 7 (pulse)

      for RHD:

      RECIRCULATION: 7 (pulse)

      FRESH: 19 (pulse)

      -

      Air Inlet Damper Actual Pulse

      No. 1 blower damper servo sub-assembly (air inlet) actual pulse

      Min.: 0

      Max.: 255

      for LHD:

      RECIRCULATION: 19 (pulse)

      FRESH: 7 (pulse)

      for RHD:

      RECIRCULATION: 7 (pulse)

      FRESH: 19 (pulse)

      -

      Electric Heater Count

      Electric (PTC) heater count

      Min.: 0

      Max.: 3

      Actual number of the heater elements to be heated displayed

      w/ PTC Heater

      Electric Heater Active Level

      Actual electric (PTC) operation level

      Min.: 0

      Max.: 3

      Actual number of the heater elements to be heated displayed

      w/ PTC Heater

      Shift Set Temperature

      Shift set temperature

      2C decr, 1C decr, Normal, 1C incr, 2C incr

      Customized value displayed

      -

      Air Inlet Mode

      Air inlet mode

      Auto or Manual

      Customized value displayed

      Customized value displayed

      -

      Compressor Mode

      Compressor mode

      Auto or Manual

      Customized value displayed

      -

      Evaporator Control

      Evaporator Control

      Auto or Manual

      Customized value displayed

      -

      ECO MODE Cancel

      ECO run cancel switch input signal

      ON or OFF

      Customized value displayed

      -

      ECO Switch

      ECO mode switch input signal

      ON or OFF

      Customized value displayed

      -

      Refrigerant Shortage Check

      Refrigerant gas volume check

      ON or OFF

      Customized value displayed

      -

      Fan speed increment control

      Fan speed increment control

      Slow, Normal, Fast

      Customized value displayed

      -

      Foot/DEF Auto Mode

      Foot/DEF Auto Mode

      ON or OFF

      Customized value displayed

      -

      Foot/DEF Auto Blow Up

      Foot/DEF Auto blower speed increase

      ON or OFF

      Customized value displayed

      -

      A/C Cutoff Signal

      The ECM sends the air conditioning control cut-off signal to the air conditioning amplifier assembly via CAN communication.

      OFF or ON

      OFF: The ECM does not send the air conditioning control cut-off signal

      ON: The ECM sends the air conditioning control cut-off signal

      -

      Refrigerant Gas Type

      Refrigerant gas type

      R134a or 1234yf

      Refrigerant gas type displayed

      -

      Blower Operation Setting (Stop&Start)

      Blower level to be 1, when Stop and Start control operate

      Blower off, Blower Level1

      Customized valve displayed

      -

      Number of Trouble Codes

      Number of trouble codes

      Min.: 0

      Max.: 255

      Number of DTCs displayed

      -

  2. ACTIVE TEST

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.

      Body Electrical > Air Conditioner > Active Test

      Tester Display

      Measurement Item

      Control Range

      Diagnostic Note

      Blower Motor

      Blower with fan motor sub-assembly

      Min.: 0, Max.: 31

      -

      Magnetic Clutch Relay

      Air conditioning system operation

      OFF, ON

      w/ Magnet Clutch

      Defogger Relay (Rear)

      Defogger relay (engine room junction block assembly)

      OFF, ON

      -

      Heater Active Level

      Heater active level

      Min.: 0, Max.: 3

      -

      Air Mix Servo Targ Pulse(D)

      No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse

      Min.: 0, Max.: 255

      for LHD:

      Operates between 5 and 92 pulses

      for RHD:

      Operates between 6 and 93 pulses

      Air Mix Servo Targ Pulse(P)

      No. 3 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse

      Min.: 0, Max.: 255

      for LHD:

      Operates between 6 and 93 pulses

      for RHD:

      Operates between 5 and 92 pulses

      Air Outlet Servo Pulse (D)

      No. 1 air conditioning radiator damper servo sub-assembly (mode) pulse

      Min.: 0, Max.: 255

      Operates between 5 and 47 pulses

      Air Inlet Damper Targ Pulse

      No. 1 blower damper servo sub-assembly (air inlet) target pulse

      Min.: 0, Max.: 255

      Operates between 7 and 19 pulses