GENERATOR REMOVAL

PROCEDURE

  1. PRECAUTION

    Note:

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

    Click hereClick here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick here

  3. REMOVE FRONT DRIVE SHAFT ASSEMBLY RH

  4. REMOVE V-RIBBED BELT

  5. REMOVE GENERATOR ASSEMBLY

    1. A210427

      Remove the terminal cap.

    2. Disconnect the connector.

    3. Remove the nut and bolt, and disconnect the wire harness from terminal B.

    4. A196712

      Remove the 3 bolts and generator assembly.