1GD-FTV ENGINE CONTROL SYSTEM SERVICE DATA
MASS AIR FLOW METER
| Tester Connection |
Condition |
Specified Condition |
| 4 (THA) - 2 (E2G) |
-20°C (-4°F) |
13.6 to 18.4 kΩ |
| 20°C (68°F) |
2.21 to 2.69 kΩ |
| 60°C (140°F) |
0.49 to 0.67 kΩ |
ENGINE COOLANT TEMPERATURE SENSOR
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
2.32 to 2.59 kΩ |
| 80°C (176°F) |
0.310 to 0.326 kΩ |
INTAKE AIR TEMPERATURE SENSOR
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
2.21 to 2.65 kΩ |
| 60°C (140°F) |
0.54 to 0.62 kΩ |
MANIFOLD ABSOLUTE PRESSURE SENSOR
| Tester Connection |
Switch Condition |
Specified Condition |
| 3 (VC) - 1 (E2) |
Ignition switch ON |
4.75 to 5.25 V |
AIR FUEL RATIO SENSOR
| Tester Connection |
Condition |
Specified Condition |
| 1 (HA1A) - 2 (+B) |
20°C (68°F) |
1.6 to 3.2 Ω |
| 3(A1A+) - 4(A1A-) |
Always |
10 kΩ or higher |