CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM(for 1ZR-FAE), Diagnostic DTC:P2822
| DTC Code | DTC Name |
|---|---|
| P2822 | Pressure Control Solenoid "J" Electrical (Shift Solenoid Valve SLP) |
DESCRIPTION
According to current from the ECM, the shift solenoid valve SLP controls primary pulley pressure in accordance with the requested gear ratio to perform gear ratio changes.
*1 |
Spool Valve |
*2 |
Sleeve |
*3 |
Solenoid Coil |
- |
- |
*a |
Hydraulic Pressure |
*b |
Current Flow to Solenoid |
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Memory |
|---|---|---|---|---|---|
P2822 |
Pressure Control Solenoid "J" Electrical (Shift Solenoid Valve SLP) |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SLP circuit. If there is an open or short in the shift solenoid valve SLP circuit, the ECM detects the malfunction, illuminates the MIL and stores this DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform the D position test in Road Test.
Check for DTCs again.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLP)
-
*a
Component without harness connected
(Transmission Wire)
Disconnect the B185 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
4 (SLP+) - 11 (SLP-)
20°C (68°F)
5.0 to 5.6 Ω
4 (SLP+) - Body ground and other terminals
Always
10 kΩ or higher
11 (SLP-) - Body ground and other terminals
Always
10 kΩ or higher
Connect the B185 transmission wire connector.
Result
Proceed to
OK
NG
NG REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here
-
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the B186 ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
B186-39 (SLP+) - B186-38 (SLP-)
20°C (68°F)
5.0 to 5.6 Ω
B186-39 (SLP+) - Body ground and other terminals
Always
10 kΩ or higher
B186-38 (SLP-) - Body ground and other terminals
Always
10 kΩ or higher
Connect the B186 ECM connector.
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
REPLACE ECM
Replace the ECM.
Result
Proceed to
NEXT
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
Result
Proceed to
NEXT