FUEL SEDIMENTER WARNING SWITCH INSPECTION
PROCEDURE
INSPECT LEVEL WARNING SWITCH
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
Float upper end position
Below 1 Ω
1 - 2
Float lower end position
10 kΩ or higher
If the result is not as specified, replace the level warning switch.