RELAY INSPECTION

PROCEDURE


  1. INSPECT STRG HTR RELAY (STEERING HEATER RELAY)


    1. B004FNE

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω
      1 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      2 - 3 Voltage not applied between terminals 1 and 2 10 kΩ or higher

      If the result is not as specified, replace the STRG HTR relay (steering heater relay).