KNOCK SENSOR INSPECTION

PROCEDURE


  1. INSPECT KNOCK CONTROL SENSOR


    1. B006C24C04
      *A for Bank 1
      *B for Bank 2
      *a

      Component without harness connected

      (Knock Control Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (for Bank 1)
      Tester Connection Condition Specified Condition
      D56-1 - D56-2 20°C (68°F) 120 to 280 kΩ
      Standard Resistance (for Bank 2)
      Tester Connection Condition Specified Condition
      D55-1 - D55-2 20°C (68°F) 120 to 280 kΩ

      Tech Tips

      If the result is not as specified, replace the knock control sensor.