SPIRAL CABLE(w/o VSC) INSPECTION

PROCEDURE

  1. INSPECT SPIRAL CABLE SUB-ASSEMBLY

    Note:

    As the spiral cable sub-assembly may break, do not rotate the spiral cable sub-assembly more than the specified amount.

    1. Remove the spiral cable sub-assembly from the vehicle.

      Click here

    2. Visually check for defects with the spiral cable sub-assembly.

      1. The defects are as follows:

        • Scratches

        • Small cracks

        • Dents

        • Chips

        • Cracks or other damage to the connector

          OK

          No defects are found.

        If any defects are found, replace the spiral cable sub-assembly with a new one.

    3. Check the spiral cable sub-assembly.

      C265162C01

      *a

      Component without harness connected

      (Spiral Cable Sub-assembly)

      -

      -

      V100144

      Interlock

      -

      -

      Note:

      When rotating the spiral cable, make sure to push on the interlock indicated in the illustration to release the interlock mechanism.

      1. Set the spiral cable sub-assembly to the center position.

        Click here

      2. Measure the resistance between each terminal of the spiral cable sub-assembly according to the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        E6-1 (CCS) - z4-3 (CCS)

        Always

        3 Ω or less

        E6-2 (ECC) - z4-4 (ECC)

        Always

        3 Ω or less

        E6-2 (ECC) - z1-7 (ECC)

        Always

        3 Ω or less

        E6-3 (EAU) - z1-8 (EAU)

        Always

        3 Ω or less

        E6-4 (AU3) - z1-9 (AU3)

        Always

        3 Ω or less

        E6-5 (AU2) - z1-10 (AU2)

        Always

        3 Ω or less

        E6-6 (AU1) - z1-11 (AU1)

        Always

        3 Ω or less

        E6-7 (SDN) - z1-12 (SDN)

        Always

        3 Ω or less

        E6-9 (HO) - z1-1 (HO)

        Always

        3 Ω or less

        E6-10 (+DP) - z1-2 (+DP)

        Always

        3 Ω or less

        E6-11 (-DP) - z1-3 (-DP)

        Always

        3 Ω or less

        E6-12 (ASL) - z1-4 (ASL)

        Always

        3 Ω or less

        E6-13 (IL+2) - z1-5 (IL+2)

        Always

        3 Ω or less

        E6-14 (SUP) - z1-6 (SUP)

        Always

        3 Ω or less

        E7-1 (D+) - z2-2 (D+)

        Always

        Below 1 Ω

        E7-2 (D-) - z2-1 (D-)

        Always

        Below 1 Ω

      3. After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        E6-1 (CCS) - z4-3 (CCS)

        Always

        3 Ω or less

        E6-2 (ECC) - z4-4 (ECC)

        Always

        3 Ω or less

        E6-2 (ECC) - z1-7 (ECC)

        Always

        3 Ω or less

        E6-3 (EAU) - z1-8 (EAU)

        Always

        3 Ω or less

        E6-4 (AU3) - z1-9 (AU3)

        Always

        3 Ω or less

        E6-5 (AU2) - z1-10 (AU2)

        Always

        3 Ω or less

        E6-6 (AU1) - z1-11 (AU1)

        Always

        3 Ω or less

        E6-7 (SDN) - z1-12 (SDN)

        Always

        3 Ω or less

        E6-9 (HO) - z1-1 (HO)

        Always

        3 Ω or less

        E6-10 (+DP) - z1-2 (+DP)

        Always

        3 Ω or less

        E6-11 (-DP) - z1-3 (-DP)

        Always

        3 Ω or less

        E6-12 (ASL) - z1-4 (ASL)

        Always

        3 Ω or less

        E6-13 (IL+2) - z1-5 (IL+2)

        Always

        3 Ω or less

        E6-14 (SUP) - z1-6 (SUP)

        Always

        3 Ω or less

        E7-1 (D+) - z2-2 (D+)

        Always

        Below 1 Ω

        E7-2 (D-) - z2-1 (D-)

        Always

        Below 1 Ω

      4. After setting the spiral cable sub-assembly to the center position, rotate the spiral cable sub-assembly 2.5 times clockwise. Then while rotating the spiral cable sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.

        Standard Resistance

        Tester Connection

        Condition

        Specified Condition

        E6-1 (CCS) - z4-3 (CCS)

        Always

        3 Ω or less

        E6-2 (ECC) - z4-4 (ECC)

        Always

        3 Ω or less

        E6-2 (ECC) - z1-7 (ECC)

        Always

        3 Ω or less

        E6-3 (EAU) - z1-8 (EAU)

        Always

        3 Ω or less

        E6-4 (AU3) - z1-9 (AU3)

        Always

        3 Ω or less

        E6-5 (AU2) - z1-10 (AU2)

        Always

        3 Ω or less

        E6-6 (AU1) - z1-11 (AU1)

        Always

        3 Ω or less

        E6-7 (SDN) - z1-12 (SDN)

        Always

        3 Ω or less

        E6-9 (HO) - z1-1 (HO)

        Always

        3 Ω or less

        E6-10 (+DP) - z1-2 (+DP)

        Always

        3 Ω or less

        E6-11 (-DP) - z1-3 (-DP)

        Always

        3 Ω or less

        E6-12 (ASL) - z1-4 (ASL)

        Always

        3 Ω or less

        E6-13 (IL+2) - z1-5 (IL+2)

        Always

        3 Ω or less

        E6-14 (SUP) - z1-6 (SUP)

        Always

        3 Ω or less

        E7-1 (D+) - z2-2 (D+)

        Always

        Below 1 Ω

        E7-2 (D-) - z2-1 (D-)

        Always

        Below 1 Ω

        If the result is not as specified, replace the spiral cable sub-assembly.