STOP AND START SYSTEM Stop and Start Cancel Switch Circuit
| DTC Code | DTC Name |
|---|---|
| Stop and Start Cancel Switch Circuit |
DESCRIPTION
Stop and start control can be disabled by pressing the stop and start system cancel switch (ecorun cancel switch assembly). The stop and start system cancel switch (ecorun cancel switch assembly) is a momentary-type switch that switches between on and off when the switch is pressed. While stop and start control is disabled, the stop and start cancel indicator light is illuminated to inform the driver.
WIRING DIAGRAM
PROCEDURE
READ VALUE USING GTS (CANCEL SWITCH)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Cancel Switch.
Read the value when the stop and start system cancel switch (ecorun cancel switch assembly) is pressed.
OK
GTS Display
Condition
Normal Condition
Cancel Switch
Stop and start system cancel switch (ecorun cancel switch assembly) is pressed
ON
Stop and start system cancel switch (ecorun cancel switch assembly) is not pressed
OFF
INSPECT STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY)
Inspect the stop and start system cancel switch (ecorun cancel switch assembly) (Click here).
CHECK HARNESS AND CONNECTOR (STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY) - BODY GROUND)
Disconnect the H119 stop and start system cancel switch (ecorun cancel switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
H119-3 (E) - Body ground
Always
Below 1 Ω
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - STOP AND START SYSTEM CANCEL SWITCH (ECORUN CANCEL SWITCH ASSEMBLY))
Disconnect the H121 engine stop and start ECU connector.
Disconnect the H119 stop and start system cancel switch (ecorun cancel switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
H121-23 (ECAN) - H119-6 (ECU)
Always
Below 1 Ω
H121-23 (ECAN) - Body ground
Always
10 kΩ or higher
H119-6 (ECU) - Body ground
Always
10 kΩ or higher
REPAIR OR REPLACE HARNESS OR CONNECTOR