PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor gear |
Connect a positive (+) battery lead to connector terminal 2 (B).
Note
Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) battery lead to connector terminals 1 (E) and 7 (DWN1) or 10 (UP1).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly LH.
CAUTION:
Initialize the power window control system after installing the power window regulator motor and regulator assembly.
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor gear |
Connect a positive (+) battery lead to connector terminal 2 (B).
Note
Do not connect a positive (+) battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) battery lead to connector terminals 1 (E) and 7 (DWN1) or 10 (UP1).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly RH.
CAUTION:
Initialize the power window control system after installing the power window regulator motor and regulator assembly.