DIFFERENTIAL VACUUM ACTUATOR INSPECTION


  1. INSPECT DIFFERENTIAL VACUUM ACTUATOR ASSEMBLY


    1. A01DXB1E01
      Text in Illustration
      *1 Shift Fork
      *a 2WD Side
      *b 4WD Side

      Measure the resistance between terminals 1 and 2.

      Standard
      0.1 to 100 Ω
    2. Measure the resistance between terminal 1 or 2 and body ground.

      Standard
      5 MΩ or more

      If the result is not as specified, replace the differential vacuum actuator.

    3. Check the actuator using one of the following methods.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Measurement Condition Specified Condition
        3 - 4

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Below 1 Ω
        3 - 4

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        10 kΩ or higher
        4 - 5

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Below 1 Ω
        4 - 5

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        10 kΩ or higher
        4 - 6

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        Below 1 Ω
        4 - 6

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        10 kΩ or higher

        If the result is not as specified, replace the actuator.

      2. Check the actuator status.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → Terminal 1

        Battery negative (-) → Terminal 2

        2WD → 4WD

        Battery positive (+) → Terminal 2

        Battery negative (-) → Terminal 1

        4WD → 2WD

        If the result is not as specified, replace the actuator.