POWER WINDOW CONTROL SYSTEM Jam Protection Function does not Operate
| DTC Code | DTC Name |
|---|---|
| Jam Protection Function does not Operate |
DESCRIPTION
This symptom may occur in all door windows.
The jam protection function operates within a specified range during the manual up or auto up operation.
PROCEDURE
PERFORM INITIALIZATION
Initialize the door window regulator (Click here).
Check if the power window auto up/down function operates (Click here).
OK
Auto up/down function operates.
END (PROBLEM DUE TO INITIALIZATION FAILURE)
CHECK JAM PROTECTION FUNCTION OPERATING RANGE
Check if the jam protection function operates for applicable power window.
Tip:The jam protection function does not operate from the fully closed position of the door glass to 4 mm (0.157 in.) below that.
OK
Jam protection function operates.
Table 1. Result Result
Proceed to
OK
A
NG (Front LH side power window)
B
NG (Front RH side power window)
C
NG (Rear power window LH)
D
NG (Rear power window RH)
E
END