STOP AND START SYSTEM Neutral Position Switch Circuit
| DTC Code | DTC Name |
|---|---|
| Neutral Position Switch Circuit |
DESCRIPTION
The neutral position sensor (neutral position switch) detects whether the shift lever is in neutral. When the shift lever in any position other than neutral, stop and start control is prohibited.
WIRING DIAGRAM
Refer to DTC P1780 (Click here).
PROCEDURE
READ VALUE USING GTS (NEUTRAL SWITCH)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.
Read the value when the shift lever is in neutral and any other position
OK
GTS Display
Condition
Normal Condition
Neutral Switch
Shift lever is in neutral
ON
Shift lever is in any position other than neutral
OFF
CHECK HARNESS AND CONNECTOR (ENGINE STOP AND START ECU - NEUTRAL POSITION SENSOR (NEUTRAL POSITION SWITCH))
Disconnect the A74 engine stop and start ECU connector.
Disconnect the D7 neutral position sensor (neutral position switch) connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
A74-26 (TMVC) - D7-1 (W1)
Always
Below 1 Ω
A74-25 (TME2) - D7-3 (F+)
Always
Below 1 Ω
A74-27 (TMN) - D7-2 (TMN)
Always
Below 1 Ω
A74-26 (TMVC) - Body ground
Always
10 kΩ or higher
D7-1 (W1) - Body ground
Always
10 kΩ or higher
A74-25 (TME2) - Body ground
Always
10 kΩ or higher
D7-3 (F+) - Body ground
Always
10 kΩ or higher
A74-27 (TMN) - Body ground
Always
10 kΩ or higher
D7-2 (TMN) - Body ground
Always
10 kΩ or higher
REPAIR OR REPLACE HARNESS OR CONNECTOR
CHECK ENGINE STOP AND START ECU (TMN TERMINAL VOLTAGE)
Measure the voltage according to the value(s) in the table below.
Table 1. Text in Illustration *a
Component with harness connected
(Engine Stop and Start ECU)
-
-
Standard Voltage
Tester Connection
Condition
Specified Condition
A74-27 (TMN) - A74-25 (TME2)
Ignition switch ON, shift lever in neutral
2.7 to 4.3 V
Ignition switch ON, shift lever in any position other than neutral
0.7 to 1.9 V