CAMSHAFT OIL CONTROL VALVE(for Bank 1) ON-VEHICLE INSPECTION

PROCEDURE


  1. REMOVE CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY

    Click here

  2. INSPECT CAMSHAFT TIMING GEAR BOLT


    1. B005QHGC01
      *a Plunger
      *b Intake Side
      *c Exhaust Side

      Check the stroke of the plunger in the center of the camshaft timing gear bolt.


      1. for Intake Side:

        Standard Stroke
        4.5 mm (0.177 in.) or more

        Tech Tips

        When pressing the plunger, there may be a stepped feeling. This is not a malfunction.

      2. for Exhaust Side:

        Standard Stroke
        2.2 mm (0.0866 in.) or more

        Tech Tips

        When pressing the plunger, there may be a stepped feeling. This is not a malfunction.

  3. INSTALL CAMSHAFT TIMING OIL CONTROL SOLENOID ASSEMBLY

    Click here