AIR PUMP INSTALLATION
PROCEDURE
INSTALL AIR PUMP ASSEMBLY
-
*1
Insulator
*2
Air Pump Assembly
*3
Air Pump Bracket
Attach the 3 fittings of the air pump insulator to install the air pump to the bracket.
Attach the 2 air pump connector clamps.
Install the air pump with bracket with the 3 bolts.
20 N*m
204 kgf*cm
15 ft.*lbf
Connect the air pump connector and attach the wire harness clamp.
-
CONNECT NO. 4 AIR INJECTION SYSTEM HOSE
-
*1
Rib
*2
Paint Mark
*a
Front
*b
Upper Side
Connect the No. 4 air injection system hose so that its paint mark aligns with the rib of the air pump as shown in the illustration.
Tip:Make sure the paint mark of the No. 4 air injection system hose is facing upward.
Make sure the direction of the hose clamp is as shown in the illustration.
-
INSTALL AIR PUMP COVER (w/ Air Pump Heater)
-
Attach the 3 claws to install the air pump cover.
Table 1. Text in Illustration *a
Inlet
Tip:Make sure the inlet of the air pump cover is oriented correctly and completely attached when installing the air pump cover.
-
INSTALL UPPER RADIATOR SUPPORT SEAL