ABSORBER CONTROL ACTUATOR INSPECTION
PROCEDURE
INSPECT ABSORBER CONTROL ACTUATOR
-
*a
Component without harness connected
(Absorber Control Actuator LH)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 1. for LH Tester Connection
Condition
Specified Condition
1 (FAL+) - 2 (FAL-)
Always
6.4 to 7.2 Ω
3 (FBL+) - 4 (FBL-)
6.4 to 7.2 Ω
If the result is not as specified, replace the absorber control actuator.
-
*a
Component without harness connected
(Absorber Control Actuator RH)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 2. for RH Tester Connection
Condition
Specified Condition
1 (FAR+) - 2 (FAR-)
Always
6.4 to 7.2 Ω
3 (FBR+) - 4 (FBR-)
6.4 to 7.2 Ω
If the result is not as specified, replace the absorber control actuator.
-