OCCUPANT CLASSIFICATION ECU INSTALLATION

PROCEDURE

  1. INSTALL OCCUPANT DETECTION ECU

    1. B341153

      Attach the claw to install the occupant classification ECU.

      Note:

      If the occupant classification ECU has been dropped, or there are any cracks, dents or other defects in the case or connector, replace the occupant classification ECU with a new one.

    2. Connect the 2 connectors.

      Note:

      When installing the occupant classification ECU, be careful that the SRS wiring does not interfere with or is pinched between other parts.

  2. INSTALL FRONT SEAT ASSEMBLY RH

    1. for Manual Seat:

      Click here

    2. for Power Seat:

      Click here

  3. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click hereClick hereClick hereClick hereClick hereClick here

  4. ZERO POINT CALIBRATION AND SENSITIVITY

  5. PERFORM DIAGNOSTIC SYSTEM CHECK

  6. CHECK SRS WARNING LIGHT